                                                                                                SAGA1-L  Series 

 

 

11

 

VHF BAND CONVERSION TABLE 

 

 

CH No.  Ch-Freq(MHz)  CH No.  Ch-Freq(MHz)  CH No.  Ch-Freq(MHz) 

310.0325 

  32 

318.3250 

  63 

326.6175 

    2 

310.3000 

  33 

318.5925 

  64 

326.8850 

    3 

310.5675 

  34 

318.8600 

  65 

327.1525 

    4 

310.8350 

  35 

319.1275 

  66 

327.4200 

    5 

311.1025 

  36 

319.3950 

  67 

327.6875 

    6 

311.3700 

  37 

319.6625 

  68 

327.9550 

    7 

311.6375 

  38 

319.9300 

  69 

328.2225 

    8 

311.9050 

  39 

320.1975 

  70 

328.4900 

    9 

312.1725 

  40 

320.4650 

  71 

328.7575 

  10 

312.4400 

  41 

320.7325 

  72 

329.0250 

  11 

312.7075 

  42 

321.0000 

  73 

329.2925 

  12 

312.9750 

  43 

321.2675 

  74 

329.5600 

  13 

313.2425 

  44 

321.5350 

  75 

329.8275 

  14 

313.5100 

  45 

321.8025 

  76 

330.0950 

  15 

313.7775 

  46 

322.0700 

  77 

330.3625 

  16 

314.0450 

  47 

322.3375 

  78 

330.6300 

  17 

314.3125 

  48 

322.6050 

  79 

330.8975 

  18 

314.5800 

  49 

322.8725 

  80 

331.1650 

  19 

314.8475 

  50 

323.1400 

 

 

  20 

315.1150 

  51 

323.4075 

 

 

  21 

315.3825 

  52 

323.6750 

 

 

  22 

315.6500 

  53 

323.9425 

 

 

  23 

315.9175 

  54 

324.2100 

 

 

  24 

316.1850 

  55 

324.4775 

 

 

  25 

316.4525 

  56 

324.7450 

 

 

  26 

316.7200 

  57 

325.0125 

 

 

  27 

316.9875 

  58 

325.2800 

 

 

  28 

317.2550 

  59 

325.5475 

 

 

  29 

317.5225 

  60 

325.8150 

 

 

  30 

317.7900 

  61 

326.0825 

 

 

  31 

318.0575 

  62 

326.3500 

 

 

 

 

Содержание saga1-l4

Страница 1: ...INSTALLATION OPERATION MANUAL...

Страница 2: ...llation operation manual is intended as an instruction manual for trained person who is in charge of installation maintenance repair etc Before installation please read the user s guide and this insta...

Страница 3: ...Layout p 5 3 0 Receiver PCB Layout P 6 3 1 Relay Board for SAGA1 L8 L6 L4 L8B L6B 3 2 Independent COM Line 3 3 Receiver Decoder Board for SAGA1 L8 L6 L4 L8B L6B 4 0 Change of Frequency P 10 5 0 Change...

Страница 4: ...V is 1 5A 3 The fuse for AC type at the COM MAIN is 10A The fuse for DC type at the COM MAIN is 20A 4 The com lines have been arranged prior to shipment if an independent COM line is required please r...

Страница 5: ...Replacing this Crystal to change the frequency on the transmitter There are two kinds of frequencies VHF and UHF are available marking with a check is the current frequency band and please make sure n...

Страница 6: ...0 RECEIVER PCB DIAGRAM 3 1 Relay Board for SAGA1 L8 L6 L4 L8B L6B 3 1 1 DC Type Fuse 20A yellow color Fuse 1 5A DC Input Remark The polarity direction of DC Input isn t required when plugging in the p...

Страница 7: ...ries 6 3 1 2 AC Type SAGA1 L8 L8B L6B SAGA1 L6 Fuse 10A Fuse 0 5A Voltage selection Jumper HI position to select higher voltage of the combination LO position to select lower voltage of the combinatio...

Страница 8: ...2S and R0 SAGA1 L4 Please refer to the above figures of receiver relay boards and if an independent COM line is required then cut the wire labeled with a white X The longer part of the wire will becom...

Страница 9: ...o PC for function setting through software SQ ADJ is used for a minimum receiving sensitivity adjustment please don t adjust arbitrarily If necessary adjusting clock wise allow receiving a weaker sign...

Страница 10: ...cedures 1 Pry up the crystal unit with a flat screwdriver 2 Remove the crystal unit from the system 3 Use a needle nose pliers to straighten both pins of the new crystal unit Note To replace a new cry...

Страница 11: ...tically into the PC board 5 Press the new crystal down into the socket Attention The frequency will be different when plugging the same crystal into the TX or RX For example T 311MHz Frequency for TX...

Страница 12: ...41 320 7325 72 329 0250 11 312 7075 42 321 0000 73 329 2925 12 312 9750 43 321 2675 74 329 5600 13 313 2425 44 321 5350 75 329 8275 14 313 5100 45 321 8025 76 330 0950 15 313 7775 46 322 0700 77 330...

Страница 13: ...2925 172 444 5850 111 428 2675 142 436 5600 173 444 8525 112 428 5350 143 436 8275 174 445 1200 113 428 8025 144 437 0950 175 445 3875 114 429 0700 145 437 3625 176 445 6550 115 429 3375 146 437 6300...

Страница 14: ...key of the new SAGA1 L crystal series provides NO and NC contact The NO is the default setting If a NC output is necessary please remove the No 8 wire R0 Start pink color from the connector and insert...

Страница 15: ...button b Press DOWN pushbutton and hold it c Press UP pushbutton 4 times and release STOP DOWN pushbuttons when the red light on the transmitter is flashing d Start the system as usual Note For SAGA1...

Страница 16: ...Manufacturer 3 RX Error LED flashes red slowly every 0 5 sec The memory of the RX is defective Send back the Manufacturer 4 The operating distance Is shorter or an intermittent operation is happened...

Страница 17: ...rogram 1 Insert the CD ROM into the CD ROM driver the program initiates automatically then you see a screen as below click OK and continue 2 The next screen you see is as below click on or Change Dire...

Страница 18: ...u on your desktop then move your mouse to Programs SAGA1 L SETUP PROGRAM and click on saga1 L CRYSTAL SETUP PROGRAM to activate III Toolbar of the program 1 On the left upper corner of the toolbar Fil...

Страница 19: ...gram either for English traditional Chinese or simplify Chinese 3 On the Page menu there are Setup Page same as and User Page same as choose the latter to change the screen to an information page whic...

Страница 20: ...receiver click on or to read the data then click OK after the new data is input and a new screen with Model and ID Code appeared as below lower picture 3 When the new settings or modification have be...

Страница 21: ...mal to activate R0 relay But R0 relay is on once activated off when pushbutton is pressed or key is turned to START again PS When it is Toggle choose Control by EMS or Bypass EMS 2 R C Function Settin...

Страница 22: ...tly Off On Control by EMS Down is on once pressed off when Up is pressed afterwards 4 East West Pushbutton Function Setting Same as Up Down Pushbutton Function Setting 5 South North Pushbutton Functio...

Страница 23: ...sec Determine the interval of LED shining time 7 Receiver Function Setting Item Title Content Description A Passive Act 1 Power Off 2 Relay Off Power Off The Power main relay is off when not receiving...

Отзывы: