MorphoAccess® VP Series - User Guide
Section 11:
Compatibility with an Access Control System
SSE-0000082427-01
M
ORPHO DOCUMENT
.
R
EPRODUCTION AND
D
ISCLOSURE
P
ROHIBITED
92
January 2011
Internal Relay activation on Access Granted result
Description
If the result of the access rights check is successful, the internal relay may be
optionally activated, for example, to directly trigger a door switch.
The duration of the activation of the internal relay can be modified by a specific
configuration key.
Access control installation using internal relay offers a lower security level, than an
installation with a central access controller which is the only one allowed opening the
door.
Figure 36: MorphoAccess® terminal internal relay
Activation key
A configuration key enables internal relay activation on access granted.
Relay activation when access is granted
app/relay/enabled = 0
Enabled
app/relay/enabled = 1
Disabled
Configuration keys
The relay aperture time can be defined by a specific configuration key (300 means 3
seconds).
Relay aperture time in 10 ms
app/relay/aperture time in 10 ms
300 (50 to 60000)