MorphoAccess® VP Series - User Guide
Section 11:
Compatibility with an Access Control System
SSE-0000082427-01
M
ORPHO DOCUMENT
.
R
EPRODUCTION AND
D
ISCLOSURE
P
ROHIBITED
102
January 2011
Then to reduce the user wait time, the value of the wait time for GND1/GND2 signal
must be defined to value a little bit greater than maximum controller answer delay.
Using LED1 and LED2 signals
When the controller provides a relay contact for each possible answer, then:
•
The “access denied" relay contact must be connected to LED1 and GND wires
•
The “access granted” relay contact must be connected to LED2 and GND wires.
Activation key
This feature is activated by a dedicated configuration key.
LED IN feature activation
app/led IN/enabled = 0
Disabled (default)
app/led IN/enabled =1
Enabled
Configuration key
The value of the wait time for the answer of distant system (LED1 or LED2 signal) is
defined by a dedicated configuration key. In case of timeout, the access is denied.
LED IN acknowledgement timeout in 10 ms
app/led IN/controller ack timeout
300 (0 to 268435455)