Manual bypass of biometric control
The default configuration of authentication mode requires a biometric control. But the
biometric check can be disabled by the MorphoAccess® terminal administrator. When
this is done, the MorphoAccess® terminal:
•
doesn’t requires the user to place a finger on the biometric sensor
•
grant the access without biometric check
According to the authentication process selected, the terminal:
•
doesn’t performs any check on the user’s identifier, as described in section
No
biometric check, no user id check
Automatic bypass of biometric control
The MorphoAccess® terminal offers an authentication mode which depends on the
user’s card content.
When the MorphoAccess® terminal detects a user’s card, it searches for a specific data
which indicates, if the biometric check is either mandatory or disabled.
This authentication mode is described in section
Authentication process specified by
User’s card
.
.
Result of access control check
The result of the access control check is signified to the user by local audible and
visible signals, as described in
Access control result
section.
Compatibility with Access Control Systems
When the identification mode is activated, the MorphoAccess® terminal supports the
features listed below:
•
Internal relay activation when the access is granted, as described in
Internal Relay
activation on Access Granted result
section
•
External activation of the internal relay, as described in
Internal Relay activation
by external button
section
•
Send access control result message to a remote system, as described in
Sending
the access control result to a distant system
section
•
Wait for distant system confirmation before granting the access, as described in
LED IN feature
section