Specification of SN200G high-performance vector convertor
Parameter description
- 149 -
U0 Group--Monitoring
U0 parameter group is used to monitor the inverter operation status information, customers can view
the panel, in order to facilitate on-site commissioning, set parameter values can also be read through
communication, for PC monitor. Wherein, U0-00 ~ U0-31 is run down and monitoring parameters P7-03
and P7-04 defined.
See specific parameters function code, parameter name and the smallest unit in Table 6-1 .
Figure 6-1 Parameters of U0
group
Function code
Name
Unit
U0-00
Running frequency (Hz)
0.01Hz
U0-01
Setting frequency (Hz)
0.01Hz
U0-02
Busbar voltage (V)
0.1V
U0-03
Output voltage (V)
1V
U0-04
Output current (A)
0.01A
U0-05
Output power (kW)
0.1kW
U0-06
Output torque (%)
0.1%
U0-07
DI input state
1
U0-08
DO output state
1
U0-09
AI1 voltage (V)
0.01V
U0-10
AI2 voltage (V)
0.01V
U0-11
AI3 voltage (V)
0.01V
U0-12
Count value
1
U0-13
Length value
1
U0-14
Loading speed display
1
U0-15
PID setting
1
U0-16
PID feedback
1
U0-17
PLC stage
1
U0-18
Input PULSE frequency (Hz)
0.01kHz
U0-19
Feedback speed (0.1Hz)
0.1Hz
U0-20
Surplus operation run
0.1Min
U0-21
AI1 voltage before calibration
0.001V
U0-22
AI2 voltage before calibration
0.001V
U0-23
AI3 voltage before calibration
0.001V
U0-24
Linear speed
1m/Min
U0-25
Current electrifying time
1Min
U0-26
Current running time
0.1Min
U0-27
Input PULSE frequency
1Hz
U0-28
Communication given value
0.01%
U0-29
Feedback speed of encoder
0.01Hz
U0-30
Display of main frequency X
0.01Hz