SAFEGREASE, SAFEOIL
ST-1100i
110i1CEN.doc
16.04.2003 Rev. 1C
6 (14)
Configuration settings
Note
Configuration settings should be changed only in connection to system
changes. These changes are usually implemented by the supplier.
Configuration mode requires a password.
Table 1.
Center operation modes
Time display code
Selected operation mode
SG1
single line grease lubrication system
SG2
dual line grease lubrication system
SG2E
dual line grease lubrication system, pressure maintaining function
OS
oil lubrication system
Display pressure unit should be either
bar
or
psi
.
Pressure monitoring unit type can be either pressure switch (
S
) or pressure transmitter (
P
).
3.1.3 Line pressure displays
In pressure transmitter operation, line pressure displays can be selected with
Settings/Pressure
button. Pressing the button will show the line 1 pressure display first.
Another press will show line 2 pressure display and if there is no line 2, program returns back to
display phase code. From line 2 pressure display program returns to display phase code by
pressing
Settings/Pressure
button.
The lines selected in pressure display are presented in the value display as codes
P1
or
P2
.
The pressure in the selected line is displayed in time display.
3.1.4 Returning to normal mode
Program returns to display program phase code (normal or alarm mode) in the following cases
1. Settings/Pressure or arrow button was last pressed more than three minutes ago.
2. both arrow buttons are simultaneously pressed down for 3 seconds
3.
Ð
-button is used to browse into phase code display
4. center is restarted