5 TECHNICAL SPECIFICATIONS
5.1 Technical data
Value Range
Unit
Description
t -20…+60
°C operation
temperature
U
in
230 ±15%, 50/60
115 ±15%, 50/60
V AC, Hz
V AC, Hz
Power input, 160 VA max.
Voltage range preset at factory and indicated in
the center name plate.
U
out
24
V DC
Control voltage, unregulated 5 A max.
The internal power supply for controlling the
system.
F1 1
(230)
2 (115)
AT (V AC)
AT (V AC)
Power input fuse, 20x5 mm glass tube fuse, slow
F2
5
AT
Control voltage fuse, 24 V for I/O-voltage, 20x5
mm glass tube fuse, slow
F3
2
AT
Electronic system fuse, 15 V, 20x5 mm glass
tube fuse, slow
200 x 300 x 120
(lxkxs)
mm Steel
casing
IP65
Protection
classification
Time settings
Lubrication cycle value can be set within 0 min 00 s – 9999 min.
Maximum pressurization time can be set within 0 min 00 s - 999 min.
All time settings are password-protected.
Power failure protection
Set values and program status at the power failure are stored in the EEPROM memory, no
batteries.