background image

SAFEGREASE, SAFEOIL 
ST-1100i 
 

 

110i1CEN.doc 

16.04.2003   Rev. 1C 

2 (14) 

 

2.2   Control Panel 

2.2.1   General 

Control panel is located inside the casing. Control panel has a 6-character display, three 
buttons and the input/output LED signals. The display and buttons can be used for setting the 
default values for lubrication program and for turning on manual control. 

2.2.2   Display 

The control panel has a 6-character 7-segment display. 

The display has been divided into two groups 

 

2-character value display gives the phase or value 

code

 

 

4-character time display gives the 

value

 corresponding to the code 

Time display 

When time display is showing a time value, the decimal point blinks at intervals of 5 seconds. 

Regardless of the code, time is always displayed the same way and as accurately as possible. 

 

Time displayed 

Display format 

Example 

0 s – 99 min 59 s 

MM.SS 

12 min 34 s = 

12.34

 

100 s -999 min 59 s 

MMM.S 

123 min 45 s = 

123.4

 

1000 min – 999 min 

MMMM. 

1234 min = 

1234.

 

> 9999 min 

9999. 

12345 min = 

9999.

 

 

2.2.3   Buttons 

Button Description 

Setting/Pressure

 

In Setting mode and while entering the password, button can be used to 
change the displayed value with arrow keys. 
Button can be used to accept transferring into manual operation, if the 
value at the display is the code for manual operation. In manual 
operation mode, pushing the button runs the function selected at display. 
In pressure transmitter use, button can be used for browsing the 
pressurized line pressure readings in normal and manual operation 
modes. 

Ð

 

Button can be used for scrolling the next display below. 
In Setting mode and entering password, button can be used for 
decreasing the displayed value, if the 

Setting/Pressure

 button is 

pressed down. 

Ï

 

Button can be used for scrolling the next display above. 
In Setting mode and entering password, button can be used for 
increasing the displayed value, if the 

Setting/Pressure

 button is pressed 

down. 

 

Содержание ST-1100i

Страница 1: ...2 Normal mode displays 5 3 1 3 Line pressure displays 6 3 1 4 Returning to normal mode 6 3 2 Extra lubrication 7 3 3 Manual control 7 3 4 Lubrication cycle counter 8 3 5 Power failure 8 3 6 Alarms 9...

Страница 2: ...EASE SAFEOIL ST 1100i 110i1CEN doc 16 04 2003 Rev 1C 4 4 5 Low and high pressure limits 12 5 TECHNICAL SPECIFICATIONS 13 5 1 Technical data 13 5 2 Connections 14 5 3 Symbols 14 6 SPARE PARTS 14 2 APPE...

Страница 3: ...edge of the center casing There is a green power supply LED signal pos 2 which is also the extra lubrication start button There is also a red alarm LED signal pos 3 which is also the alarm acknowledg...

Страница 4: ...59 s MM SS 12 min 34 s 12 34 100 s 999 min 59 s MMM S 123 min 45 s 123 4 1000 min 999 min MMMM 1234 min 1234 9999 min 9999 12345 min 9999 2 2 3 Buttons Button Description Setting Pressure In Setting m...

Страница 5: ...mit Signal is lit when the container is empty which means that the low limit switch is closed INTERLOCKING Lubrication point operation information Signal is lit when the lubrication point is not in op...

Страница 6: ...lubrication system pressure switch operation pressurization Extra delay Delay time left dC Pressure discharge waiting time in pressure transmitter operation disCharge Discharge time used CL Center is...

Страница 7: ...when button is pressed and vice versa when button is pressed Display codes Description HL Manual mode Hand Lubrication CC Lubrication cycle counter Cycle Counter LC Lubrication cycle set value Lubrica...

Страница 8: ...n pressure transmitter operation line pressure displays can be selected with Settings Pressure button Pressing the button will show the line 1 pressure display first Another press will show line 2 pre...

Страница 9: ...oil lubrication systems OS line is pressurized once Interval counter is reset when the last pressurization is started which means that the next automatic mode pressurization is performed always accor...

Страница 10: ...atic mode by selecting the code OFF into the value display and by pressing Settings Pressure button after that System also returns automatically to Automatic mode if 60 minutes has gone since Manual c...

Страница 11: ...n pressurization is started The same line will be pressurized again when pressure switch is open and the alarm has been acknowledged by pressing the Alarm acknowledgement button on the center cover Pr...

Страница 12: ...4 1 General Center settings can be divided into two groups Set values Configuration settings Set values are lubrication system values for example lubrication cycle and maximum pressurization time Set...

Страница 13: ...browsing to code PASS by means of button Display code Description C C Lubrication cycle counter Cycle Counter L C Lubrication cycle set value Lubrication Cycle L P Maximum pressurization set value Lu...

Страница 14: ...isplay will show a phase code CL When the center is closed only manual control operation is possible 4 4 4 Pressurization delay time coefficient This feature is available only in pressure switch opera...

Страница 15: ...the system F1 1 230 2 115 AT V AC AT V AC Power input fuse 20x5 mm glass tube fuse slow F2 5 AT Control voltage fuse 24 V for I O voltage 20x5 mm glass tube fuse slow F3 2 AT Electronic system fuse 15...

Страница 16: ...V 5 A max Alarm two voltageless exchange switches loading 50V 1A max Cable channels in the casing 5 channels for 7 10 mm cable diameters 1 channel for 10 14 mm cable diameters 5 3 Symbols ST 1100i xxx...

Страница 17: ......

Страница 18: ......

Отзывы: