background image

MAXILUBE 
IF-105 
 

 

MUIF3AEN.doc 

21.4.2005   Rev. 3A 

 

USER INTERFACE IF-105 

CONTENTS 

1 GENERAL DESCRIPTION ................................................................................................................................1

 

2 DESIGN .............................................................................................................................................................1

 

2.1 LED-signals for channels ............................................................................................................................1

 

2.2 LED-signals for operation ...........................................................................................................................1

 

2.3 Buttons ........................................................................................................................................................2

 

2.4 Display.........................................................................................................................................................2

 

3 OPERATION......................................................................................................................................................3

 

3.1 Normal mode...............................................................................................................................................3

 

3.1.1 Functions ..............................................................................................................................................3

 

3.1.2 Phase codes for normal mode and alarm mode ..................................................................................4

 

3.1.3 Normal mode displays..........................................................................................................................5

 

3.1.4 Line pressure displays..........................................................................................................................5

 

3.2 Power failure ...............................................................................................................................................6

 

3.3 Alarms .........................................................................................................................................................6

 

3.3.1 Low level alarm ....................................................................................................................................6

 

3.3.2 Pressure alarm .....................................................................................................................................6

 

3.3.3 Alarm from LG-ind doser operation indicator .......................................................................................7

 

3.3.4 Alarm from air pressure switch of grease spray system ......................................................................7

 

3.4 Manual operation ........................................................................................................................................7

 

4 SETTINGS .........................................................................................................................................................8

 

4.1 General........................................................................................................................................................8

 

4.2 Entering password ......................................................................................................................................8

 

4.3 Entering settings .........................................................................................................................................8

 

4.3.1 Lubrication cycle counter......................................................................................................................8

 

4.3.2 Lubrication cycle...................................................................................................................................9

 

5 TECHNICAL SPECIFICATION..........................................................................................................................9

 

5.1 Technical specifications ..............................................................................................................................9

 

5.2 Symbols ......................................................................................................................................................9

 

 

   1 APPENDICE 

Содержание MAXILUBE IF-105

Страница 1: ...e 4 3 1 3 Normal mode displays 5 3 1 4 Line pressure displays 5 3 2 Power failure 6 3 3 Alarms 6 3 3 1 Low level alarm 6 3 3 2 Pressure alarm 6 3 3 3 Alarm from LG ind doser operation indicator 7 3 3...

Страница 2: ...channel 1 is not in alarm mode LED signal is blinking when channel 1 is selected on the display CH2 Red LED signal is lit when channel 2 is in alarm mode Green LED signal is lit when channel 2 is not...

Страница 3: ...n browsing the set values the button is used to go to setting mode When a button is pressed all green LED signals are lit for a moment This indicates that information that a button has been pressed ha...

Страница 4: ...D signal P indicates that pressurization is in progress Pressurization can be stopped with SET button Pressurization time display and setting can be changed from seconds to minutes with factory settin...

Страница 5: ...closed AGr Lubricant barrel low level alarm Alarm Grease ALP Pressure low alarm line pressure does not rise high enough during pressurization time Alarm Low Pressure AHP Pressure high alarm line press...

Страница 6: ...P n s Code is used only in pressure switch operation HL Manual operation setting On manual operation mode OFF automatic operation mode Decimal points are used to separate thousands in lubrication cycl...

Страница 7: ...ed on the display is in alarm mode the red LED signal for line L1 line L2 or pressurization P is blinking 3 3 1 Low level alarm The channel triggers a low level alarm stops pressurization and goes int...

Страница 8: ...isplayed Lubrication continues normally despite the alarm This feature is different from any other alarms Alarm can be reset with SET button 3 3 4 Alarm from air pressure switch of grease spray system...

Страница 9: ...ctly code ACC is displayed and set values can be changed during the next 10 minutes 9 If password has not been entered correctly code Err is displayed and display returns to normal mode Note Set value...

Страница 10: ...nk 6 Move the decimal point to the desired location with button 7 The set value is saved in the memory with SET button 5 TECHNICAL SPECIFICATION 5 1 Technical specifications Quantity Value Unit Descri...

Страница 11: ......