MAXILUBE
IF-105
MUIF3AEN.doc
21.4.2005 Rev. 3A
2 (9)
2.3 Buttons
Note
The operation of the buttons is directed to the channel which is selected on
the display.
Button Description
Ï
In normal operation mode, the button is used to browse set values on the
display.
In setting mode, the button is used to change the value on the display.
Î
In normal operation mode, the button is used to browse line pressure displays.
In setting mode, the button is used to move to the next character of the
display.
When browsing the set values, the button is used to return to normal mode.
SET
In normal mode, the button is used to start extra lubrication, to stop
pressurization or reset an alarm.
In setting mode, the button is used to save the value that has been changed.
When browsing the set values, the button is used to go to setting mode.
When a button is pressed, all green LED-signals are lit for a moment. This indicates that
information, that a button has been pressed, has been transmitted forward.
2.4 Display
Note
The operation of the display is directed to the channel which is selected on
the display.
User interface has a display of 3 characters and 3 decimal points.
The display shows time and in pressure transmitter operation also pressure.
Time display
Lubrication cycle set value and elapsed interval are shown on the display as hours and
minutes. Decimal point is used to separate hours and minutes.
Time displayed
Display format
Example
0 min -59 min
H.MM
12 min =
0.12
1 h -9 h 59 min
H.MM
1 h 20 min =
1.20
10 h -99 h 50 min
HH.M
12 h 50 min =
12.5
100 h – 999 h
HHH.
120 h =
120.
Set value for maximum pressurization time and elapsed pressurization time are shown on the
display as seconds without the decimal point.