MAXILUBE
IF-105
MUIF3AEN.doc
21.4.2005 Rev. 3A
1 (9)
USER INTERFACE IF-105
1 GENERAL DESCRIPTION
IF-105 is a user interface for MaxiLube lubrication system.
Lubrication programming, alarm resetting and lubrication event monitoring can be performed
with the user interface.
2 DESIGN
Note
Numbers in brackets are part numbers of drawing 461981A.
The IF-105 user interface includes a display (pos.1), LED-signals for lubrication lines and
pressurization (pos.2), browsing buttons (pos.3), a setting/function button (SET) (pos.4) and
LED-signals for lubrication channels (pos.5).
2.1 LED-signals for channels
Note
LED-signals
CH1
and
CH2
for lubrication channels are in use only in
systems with two channels.
LED-signal Description
CH1
Red LED-signal is lit, when channel 1 is in alarm mode.
Green LED-signal is lit, when channel 1 is not in alarm mode.
LED-signal is blinking when channel 1 is selected on the display.
CH2
Red LED-signal is lit, when channel 2 is in alarm mode.
Green LED-signal is lit, when channel 2 is not in alarm mode.
LED-signal is blinking when channel 2 is selected on the display.
2.2 LED-signals for operation
Note
LED-signals indicate the operation of the channel which is selected on the
display.
LED-signal Description
L1
Green LED-signal is lit, when main line 1 is pressurized.
Green LED-signal is lit during interval, when main line 1 has been pressurized
last.
Red LED-signal is blinking, when main line 1 is in pressure alarm mode.
L2
Green LED-signal is lit, when main line 2 is pressurized.
Green LED-signal is lit during interval, when main line 2 has been pressurized
last.
Red LED-signal is blinking, when main line 2 is in pressure alarm mode.
P
Green LED-signal is lit, when pressurization phase is in progress.
Red LED-signal is blinking, when the pumping center is in low level alarm
mode.
Содержание MAXILUBE IF-105
Страница 11: ......