SAFEGREASE 2 
MAXILUBE 
 

 

MMAX1DEN.doc 

30.05.2005   Rev. 1D 

2 (9) 

 

3   OPERATION 

When pressurization starts, control unit opens both the line to be pressurized and the pump 
solenoid valves. Pressure air starts the pump and opens the line directional valve. 
Pressurization continues until the pressure control unit of the line reaches the 
acknowledgement pressure level. After acknowledgement the control unit closes the solenoid 
valves, the pump stops and pressure discharges from the line to the lubricant barrel. 

If the lubricant level in the barrel reaches the low limit level during pumping, the low level switch 
sends an alarm to the control unit and pumping is stopped. The alarm can be disabled by 
changing the lubricant barrel and resetting the alarm at the control unit. 

3.1   Start-up 

Caution 

Ensure that the pumping center is turned off when the connections are 
made. 

3.1.1   Maxilube-ECO 

Note 

Numbers in brackets are part numbers of drawing 461983A. 

 

1.  Ensure that the surroundings of the pumping center are clean. Impurities in the system 

prevent trouble-free operation and cause damage when reaching the lubrication point. 

2.  Check the state of the lubricant barrel (1). Damages on the surface prevent the lowering of 

the follower plate (2). 

3.  Remove the lid from the barrel and press the follower plate tightly to the barrel above the 

lubricant. Ensure that air is being removed under the follower plate and that the central unit 
(3) of the follower plate is filled with lubricant. 

4.  Place the lid (4) on top of the lubricant barrel. Fasten the lid with wing screws on the 

lubricant barrel. 

5.  Place the pump (5) through the lid into the follower plate central unit. Ensure that the pump 

is attached to the follower plate. 

6.  Fasten the pressure air hoses (6) to the bottom plate connections A1 and A2, the tank 

hose for lubricant (7) to the bottom plate connection T and the grease filter (8) to the 
bottom plate connection P (Figure 1). 

7.  Fasten the low level switch (9) to the pump. 

8.  Connect the low level switch cable (13) and the cables of the channel pressure control 

units and shut-off valves to the pumping center as described in the electrical drawings. 

9.  Connect the hose for pressure air to the pressure air connection (14) of the pump. 

10. Ensure that the lubrication device (16) of pressure air regulator (15) is filled with 

recommended oil. 

11.  Adjust the pressure air lubrication in pumping center with lubrication control device (17) of 

the pressure air regulator. Min. 1 turn open with VG32 –class oil. 

12.  Set the pressure of pumping center pressure air to 4 bar (60 psi) (19) with pressure air 

control device (18) of the pressure air regulator. 

13.  Fasten the plug to the tank connection (20) of the pump. 

14.  Connect the pressure hose (21) to the pressure connection (22) of the pump. 

15.  Start the pump in manual operation mode of the control unit or with pressure air manual 

control screw (23) of the pumping center's solenoid valve group, see chapter 

3.3   Manual 

operation

 . When manual control screws are used, remove the cover plate (11) and the nut 

(12) below the plate. After this remove the pumping center cover (10). 

16.  After the pressure hose is filled, stop the pump and connect the hose to the grease filter. 

Содержание MAXILUBE 2

Страница 1: ...STA 1 3 OPERATION 2 3 1 Start up 2 3 1 1 Maxilube ECO 2 3 1 2 Maxilube STA 3 3 2 Changing the lubricant barrel 4 3 2 1 Maxilube ECO 4 3 2 2 Maxilube STA 5 3 3 Manual operation 6 4 SETTINGS 7 5 TECHNIC...

Страница 2: ...vered with the following additional pieces of equipment barrel lid pos 13 follower plate pos 14 barrel low level switch pos 15 and grease filter pos 16 Note The follower plate is not used with grease...

Страница 3: ...id 4 on top of the lubricant barrel Fasten the lid with wing screws on the lubricant barrel 5 Place the pump 5 through the lid into the follower plate central unit Ensure that the pump is attached to...

Страница 4: ...n and cause damage when reaching the lubrication point 2 Check the state of the lubricant barrel 1 Damages on the surface prevent the lowering of the follower plate 2 3 Remove the lid from the barrel...

Страница 5: ...ntrol device The maximum pressure of the pumping center should be set approximately 20 higher than the pressure by which the pressure control unit acknowledgement pressure is reached For example if th...

Страница 6: ...TA Note Numbers in brackets are part numbers of drawing 461993B 1 Ensure that the surroundings of the pumping center are clean Impurities in the system prevent trouble free operation and cause damage...

Страница 7: ...ssure gauge at the pumping center rises to 200 250 bar 3000 3600 psi turn the manual control screw of solenoid valve MV3 to its initial position 90 counter clockwise to stop the pump 4 Let the pressur...

Страница 8: ...350 bar 2900 5000 psi 5 TECHNICAL SPECIFICATION 5 1 Technical specifications Quantity Value Unit Description t 10 50 14 122 C F Operation temperature p 4 7 60 100 bar psi Pressure range for pneumatic...

Страница 9: ...is used 230 Power input 230 V Control voltage if external control is used D IF105 User interface IF 105 X External control E R Connections R threads U Connections NPT threads F A Options LG ind spray...

Страница 10: ...lid set assembly drawing 361189A See MAX LIDSET 1 1 ECO 590 lid set assembly drawing 361188A 6 2 Maxilube STA See MAX LIDSET 1 4 STA 370 lid set assembly drawing 361191A See MAX LIDSET 1 1 STA 590 li...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Отзывы: