4 SETTINGS
Warning
The pressure in the pneumatic system must be regulated so that the
pressure at the pumping center cannot under any circumstances exceed
350 bar (5000 psi).
In Safegrease 2 system, the pressure ratio of the pneumatic pumps used is normally 1:50. The
pressure level in the pneumatic system can be set at 4 to 7 bar (60–100 psi) with the pressure
air control device of the pressure air regulator located at the pumping center, in which case the
line pressure generated by the pumping center is 200 to 350 bar (2900–5000 psi).
5 TECHNICAL SPECIFICATION
5.1 Technical specifications
Quantity Value
Unit
Description
t -10…+50
+14…+122
°C
°F
Operation temperature
p 4–7
60–100
bar
psi
Pressure range for pneumatic system
U 24
±10%
115 ±10%; 50/60
230 ±10%; 50
V DC
V AC, Hz
V AC, Hz
Control voltage
U
115 ±10%; 50/60
230 ±10%; 50
V AC, Hz
V AC, Hz
Power input
P
150
W
Power consumption max
m 13
kg Weight
See drawing 461985
mm
Dimensions
5.2 Connections
Inputs
•
pressure air, pipe Ø 12 mm or Ø 1/2”
•
low level switch, connector M12
•
pressure control, 2 pcs, connector M12
•
power input, PG 13,5 cable gland
Outputs
•
lubricant, 2 pcs (line 1 out, line 2 out), pipe Ø 12 mm or Ø 1/2”
•
pumping center 2 or shut-off valve, 2 pcs, connector M12
Cable channels in the bottom plate
•
PG 11 cable gland, 4 pcs, for 4-10 mm cable diameters