17
MX3+ v.2.02 EN
Configuration
OTHER CODES
CODE
DATA
COMMENTS
Detect dial tone
*83*
- #
0 = Off
1 = On (default)
Set to off if SafeLine has problem to detect the
dial tone.
Receipt to alarm
receiver with P100
protocol
*84*
- #
Select which message(s) to send to the alarm
receiver at an alarm call.
0 = None (default)
1 = Start of alarm
2 = Start+end of alarm
Break on new alarm
*86*
- #
Disconnects a call longer than 60 seconds at new
activation of the alarm button and calls the next
emergency call number.
0 = Off
1 = On (default)
Alarm button delay
time
*87*
- - #
Delay time from pressing the alarm button until
activating the alarm.
00-25 seconds. Default = 05
Outputs
*88*
- - #
The first digit specifies the output, i.e Output 1 or
Output 2.
The second digit specifies the function:
0 = Pictogram
(Output 1 - Yellow, Output 2 - Green)
1 = Activate with DTMF 8/9
(Output 1 - DTMF 8, Output 2 - DTMF 9)
2 = System failure
3 = Alarm
Example:
*88*11# - Output 1, Activate with DTMF 8
*88*23# - Output 2, Alarm
Alarm button type
*89*
- #
0 = Normally-open contact, N/O (Default)
1 = Normally-closed contact, N/C