15
MX3+ v.2.02 EN
Configuration
OTHER CODES
CODE
DATA
COMMENTS
Emergency signal in
speaker
*71*
- #
The speaker siren will sound at emergency
call.
0 = Off (default)
1 = On
Ring-tone timeout
*72*
- - #
Number of ring signals before dialling the
next number (default = 08).
Additional input
function
*73*
- #
Selects input function:
0 = None (Default)
1 = Filter, blocks the alarm input when active.
2 = LMS (Lift Monitoring System), sends a lift
monitoring alarm at input activation.
3 = Clear/Maintenance
4 = Call Delay
Additional input type
*74*
- #
0 = Normally-open contact, N/O (Default)
1 = Normally-closed contact, N/C
Hotline
*75*
- #
Phone connects directly to a fixed receipient
without phone number
0 = Standard phone line (default)
1 = Hotline
Volume control
*76*
- #
Adjustabel volume, between 1-6.
(Default = 4)