14
MX3+ v.2.02 EN
Configuration
TEST ALARM
BATTERY ALARM
CODE
DATA
COMMENTS
LMS phone number
*16*
- - - - - - - - - # LMS (Lift Monitoring System) phone number to alarm
receiver or SLCC.
Test alarm
*17*
- - - - - - - - - # Phone number to test alarm receiver or SLCC.
Days between tests
*27*
- - #
Number of days between test alarms, 00-99 days.
Always two digits.
Max 3 days according to EN 81-28.
00 = No test alarms
Test alarm protocol
*31*
- #
0 = P100
3 = CPC
4 = Caller ID
ALARM TYPE
CODE
DATA
COMMENTS
Alarm type 1st number
*41*
- - #
Only when using CPC as alarm protocol
Normally 10 or 27, check with your alarm company!
Alarm type 2nd number
*42*
- - #
Alarm type 3rd number
*43*
- - #
Alarm type 4th number
*44*
- - #
Alarm type LMS
*45*
- - #
LMS (Lift Monitoring System)
(Battery alarm)
Normally 17
Alarm type Test alarm
*46*
- - #
Normally 26
DISTRESS MESSAGE
CODE
DATA
COMMENTS
Record distress message
played in the lift car
*51*
”Speak” # This message will be played in the lift car when the
emergency lift telephone starts calling the alarm
centre. Make sure that there is no noise in the
background when recording the message.
Example of message:
Please do not panic, the emergency telephone is
now calling the emergency call centre.
Record alarm message
from Lift Car to alarm
central
*52*
”Speak” # This message will be played to the alarm receiver
and in the car when the call is answered. Make
sure that there is no nose in the background when
recording the message.
Example of message:
This is an alarm from the lift on 5th avenue.
To hear the quality of the message, press “1”.
To terminate the call press “#”.
Options for the recorded
distress message
*61*
*61*
- #
#
To play the recorded message, press the desired
parameter followed by #.
Options for the recorded
message from Lift Car
*62*
*62*
- #
#
0 = Disable recorded message.
1 = Enables recorded message.