Cause
Error Code
Effect
Notes / Recommended Intervention
MDB slave error detected
35
Warning only
Warning report only in the LOG.
Slow coffee boiler warm-up
36
Vending machine out of service
Check the coffee boiler (connections, thermostats)
Credit Manager warning
42
Warning only
The credit management system has
overcome a possible blocking condition
(credit watch-dog enabling).
Watchdog operation
72
Warning only
Warning report only in the LOG.
MDB coin return error
message
80
Warning only
Warning report only in the LOG.
Check the coin return.
Consumed softener filter signal
83
Warning only
Maintain the softener filter
I stop funds intervened
84
Coffee products disabled
Remove and empty the coffee grounds drawer
Boiler filling procedure
not completed
successfully
85
Blocked V. M.
Repeat automatic filling (turn the vending machine off
and on again)
Check water circuit
Sensor type incorrect
(probably a wrong VM
model has been selected)
87
Blocked V. M.
Select the correct vending machine model
(System Management Menu)
Check connections of temperature
sensors
Flowmeter pulses not
detected during loader
steam cycle
88
Steam stop
Check flowmeter, water pump and steam
solenoid valve operation.
Steam boiler sensor error
92
Beverages with steam not
available
Check the steam boiler (connections, thermostats,
temperature sensor).
Both boilers out of service
93
Blocked V. M.
Check boilers (connections, thermostats,
temperature sensor)
Slow steam boiler warm-up
94
Check the steam boiler (connections, thermostats,
temperature sensor).
Coffee boiler filling failed
95
Coffee beverages not available
Check the water circuit (pump, flowmeter).
No dreg drawer detected
98
"Insert coffee grounds
drawer" message displayed
Warning report only in the LOG.
Insert coffee grounds drawer.
Содержание Phedra Evo D.A. 5P2015