English
11
86
11
TROUBLESHOOTING
The following table indicates the possible error or alarm causes which may lead to a partial or total arrest of the vending
machine.
The following is reported for each cause:
• associated code, reported in the error LOG;
• the consequence of the occurred event on the vending machine operation when the VM works as a single machine for hot
beverage brewing;
• the consequence of the occurred event on the vending machine operation when the VM works in association with one or two spiral slaves;
• a note to help identifying the warning and restore the normal operation.
Cause
Error Code
Effect
Notes / Recommended Intervention
Flowmeter pulses not detected
1
Vending machine out of service
Check the water network connection or fill in the
water tank
Coffee dosing unit filling
not detected (no more
coffee?)
2
Coffee beverages not
available
Fill in the coffee bean hopper.
Or check the coffee dosing unit operating condition.
Group gearmotor
movement not detected
3 and 4
Coffee beverages not
available
Check the brew group gearmotor and/or
the positioning microswitches.
reading of coffee boiler
temperature sensor out
of range
14
Vending machine out of
service
Check the coffee boiler (connections,
thermostats, temperature sensor)
Brew group not detected
20
Coffee beverages not
available
Warning report only in the LOG.
“No more coffee beans” message is displayed.
Check the brew group inserting status.
Water tank not detected
21
The message requesting to
insert the water tank
appears on the display.
Warning report only in the LOG.
Machine blocked and waiting for
servicing.
Insert water tank.
Abnormal coffee brewing
flow detected
22
Coffee beverages not
available
Check the brew group cleaning.
Set a coarser coffee grind.
Check the flowmeter.
pump used beyond
maximum time limit
23
Warning only
Check:
beverage programming, flowmeter and
water circuit.
No filling of the instant
product boiler
24
Models with 2 boilers
==>beverages with instant
products not available
Check the instant product boiler water
circuit.
Instant Models ==> Vending
machine out of service
Decimal point position
setting not consistent
with the payment system
31
Vending machine out of
service
Check for consistency between decimal
point settings in the vending machine and
in the payment system
Credit management restart
32
Warning only
Warning report only in the LOG.
Warning for normal
situation restoring after
abnormal flow
34
Warning only
Warning report only in the LOG.
Check the ground coffee granulometry.