7.5.Carafe connection and hot/steam water dispenser
7.6. Removing tap
7.7. Pump
7.8. Flow-meter
1) Unscrew the screws highlighted and remove the front cover body graft carafe
2) Remove teflon tube graft carafe
1
2
1
1
Unscrew the screws highlighted
and release the insert bottom casing for
convenient access to the dismantling of the tap
Unscrew the screws
highlighted
, remove
the hydraulic con-
nections and remove
the tap
Disconnect the water
circuit connections (A)
and electrical connections
(B), loosen the safety
valve (C) and slide the
pump off the brackets
(D).
A
B
D
D
C
A
A
Lift the flow meter
out of the casing
assembly
and
remove the electrical
and water circuit
connections.
GAGGIA VELASCA 07 DISASSEMBLY