Engineering manual - SAB 193-233-283 S A-frame (including ATEX)
110/175
008831 en 2022.02
Max. variation at 180°C rotation
mm
Pos. 1
horizontal
0–0.10
Pos. 1
vertical
slide bearings
0.05–0.15 above shaft with slide bearings
roller or
slide + slide bearings
0–0.10
Pos. 2
0–0.10
Table 26
Achieving correct centre height
•
Turn the coupling so that the alignment gauge is faced vertically down.
•
Guide the measuring pin (pos. 1) towards the coupling flange using a 1.0 mm feeler
gauge, and fix the pin.
•
Remove the feeler gauge.
•
Rotate the coupling 180° and measure the increase in distance "z" from one millimetre
using feeler gauges.
•
Lift the motor by placing shims of a thickness equal to half the value of "z" under all four
feet.
•
After securing the motor, repeat the measurement and compare the result to the values
in Table 26, pos. 1 vertical.
Achieving parallel shafts in vertical plane
The motor is now positioned at the correct height. What remains is to push and turn the motor
at the level on which it is already lined up.
•
Turn the coupling so that the alignment gauge faces out to one side horizontally.
•
Guide both measuring pins towards the coupling with a 1.0 mm feeler gauge in
between.
•
Turn the coupling 180° and use feeler gauges to measure deviations from one milli-
metre at both pins.
•
Move and turn the motor and repeat this measurement.
•
Align the motor in accordance with pos. 1 horizontal and pos. 2 in Table 26.
•
Check that the distance C is still correct according to the coupling type.
Remember that the motor must be firmly secured during any measurement.
Содержание SAB 193 S
Страница 1: ...SAB 193 233 283 S A frame including ATEX Screw compressor units Engineering manual EN...