Higher vibration levels may occur if:
–
the motor and compressor have not been aligned in accordance with
requirements.
–
the compressor runs at an incorrect Vi ratio (screw compressors only).
–
the piping connections have been executed in a way that makes them force pull
or push powers on the compressor unit, or transfer vibrations to the unit caused
by natural vibrations or connected machinery.
–
the vibration dampers have not been fitted or loaded correctly as indicated in
the foundation drawing accompanying the order.