Network Configuration
The R5 SUPREME CDU uses Light Weight Ethernet (LWE) to communicate with the R5
Navigation Sensor as well as other R5 SUPREME CDU units in multi-display or redundant
configurations. It is therefore necessary to configure the IP numbers and a Light Weight
Ethernet network IDs for both the R5 SUPREME CDU and the R5 Navigation Sensor. The
LWE ID con
sists of two letters (always “SN” for the R5 SUPREME CDU and “GN” for the R5
Navigation Sensor) and four digits. The LWE ID must be unique for all equipment connected
to the LWE network.
Figure 17 - Network Configuration
Note:
Make sure the R5 Navigation Sensor target is properly connected to the R5 SUPREME
CDU, either by LWE Network or direct interconnection. If so, it shall appear as a target in the
Select Navigation Sensor
list. Otherwise control that the R5 Navigation Sensor is powered
and double check the connection. P
ress the button “Refresh List”, to search for R5 Navigation
Sensor units on the LWE network.
Figure 18
– Select Navigation Sensor/ Configure Navigation Sensor Network