RYM
ASKON
®
200-Modbus
Modbus Slave
User Manual
© S+S REGELTECHNIK GMBH
| THURN-UND-TAXIS-STR.22 | 90411 NÜRNBERG | GERMANY | FON +49(0)911 519470 |
Page 34 of 55
Register Name
Register
Address
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
config_display_
value_0
256
0x0100
unit_modbus
[0x1]
unit
[0x1]
CAL
[1]
semantic_meaning
[0x01]
257
0x0101
VSA
[1]
VEU
[1]
DSSA
[1]
DSEU
[1]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[1]
[0]
config_display_
value_1
258
0x0102
unit_modbus
[0xA]
unit
[0xA]
CAL
[1]
semantic_meaning
[0x04]
259
0x0103
VSA
[1]
VEU
[1]
DSSA
[1]
DSEU
[1]
[0]
[0]
[0]
[0]
[1]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_2
260
0x0104
unit_modbus
[0x1]
unit
[0x1]
CAL
[1]
semantic_meaning
[0x05]
261
0x0105
VSA
[1]
VEU
[1]
DSSA
[1]
DSEU
[1]
[0]
[0]
[0]
[0]
[1]
[0]
[0]
[0]
[0]
[0]
[1]
[0]
config_display_
value_3
262
0x0106
unit_modbus
[0xB]
unit
[0xB]
CAL
[1]
semantic_meaning
[0x07]
263
0x0107
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_4
264
0x0108
unit_modbus
[0x8]
unit
[0x8]
CAL
[1]
semantic_meaning
[0x0E]
265
0x0109
VSA
[1]
VEU
[1]
DSSA
[1]
DSEU
[1]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_5
266
0x010A
unit_modbus
[0x1]
unit
[0x1]
CAL
[1]
semantic_meaning
[0x03]
267
0x010B
VSA
[1]
VEU
[1]
DSSA
[1]
DSEU
[1]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[1]
[0]
[0]
config_display_
value_6
268
0x010C
unit_modbus
[0x0]
unit
[0x0]
CAL
[0]
semantic_meaning
[0x00]
269
0x010D
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_7
270
0x010E
unit_modbus
[0x0]
unit
[0x0]
CAL
[0]
semantic_meaning
[0x00]
271
0x010F
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_8
272
0x0110
unit_modbus
[0x0]
unit
[0x0]
CAL
[0]
semantic_meaning
[0x00]
273
0x0111
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_9
274
0x0112
unit_modbus
[0x0]
unit
[0x0]
CAL
[0]
semantic_meaning
[0x00]
275
0x0113
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_10
276
0x0114
unit_modbus
[0x0]
unit
[0x0]
CAL
[0]
semantic_meaning
[0x00]
277
0x0115
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_11
278
0x0116
unit_modbus
[0x0]
unit
[0x0]
CAL
[0]
semantic_meaning
[0x00]
279
0x0117
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
config_display_
value_12
280
0x0118
unit_modbus
[0x0]
unit
[0x0]
CAL
[0]
semantic_meaning
[0x00]
281
0x0119
VSA
[0]
VEU
[0]
DSSA
[0]
DSEU
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]