700-1000 - B
June - 2010
9
Unpacking & Assembly Procedure for the PAL – Portable Aquatic Lift
1. Cut open enclosure bag at base of unit - carefully remove plastic.
2. Cut internal bands – remove mast assembly, seat assembly and housing. Lift assembly by mast and
seat arm. Do not lift mast assembly by actuator as this could damage the actuator.
3. Remove accessory box.
4. Remove handle from frame.
5. Remove main frame from pallet. Position main frame close to pallet and lock both rear wheels.
6. Remove bracing from pallet to allow access to counterweights and carefully transfer 24 counterweights
from pallet and attach restraining strap following instructions on page 7.
7. Place housing on frame.
8. Remove 2 lock nuts and washers from mast mounting hub on base assembly.
9. Position mast assembly through housing and attach to studs located on base assembly with lock nuts
and washers. Fully tighten with 3/4” or 19mm socket wrench.
10. Remove plastic from mast assembly. Remove 3/8”(10mm) bolt and nut from actuator arm end.
Following the illustration - attach actuator end to end of actuator arm using the same 3/8”(10mm) bolt and
nut. Fully tighten bolt and nut using 9/16”(14mm) socket and wrench
.
11. Remove twist-tie and uncoil actuator cable at bottom of mast.
12. Lift and slide housing part way up mast to gain access to frame area under housing.
13. Run actuator cable along with 24v motor cable across top of weights and insert through hole in rear of
housing near Control Box.