background image

SA-PAM-SAN-Eth 

User Manual  

 

S-Access GmbH

 

 

Tel: +41 44 700 31 11 

Oberhausenstrasse 47 

Page

 29 

of

 32

 

Fax: +41 44 700 31 03 

8907 Wettswil a/A 

 

Email: 

[email protected]

 

Switzerland   WEB: 

www.s-access.ch

 

11 CONNECTOR’S DESCRIPTION 

11.1 DSL Connector 

Type: RJ-45, 8 pin

 Number 

Signal 

Assignment 

 

1,2 NC 

LB,a 

tip (4W model only) 

4 LA,a 

tip 

5 LA,b 

ring 

LB,b 

ring (4W model only) 

 

 

7,8 NC 

 

RJ-45

 

1

 

8

 

 

11.2  DSL Connector for SRL units 

Type: RJ-45, 8 pin

 Number 

Signal 

Assignment 

 

LB,a  

tip (4W model only)- 

LB,b  

ring (4W model only) 

3 NC 

4 LA,a 

tip 

5 LA,b 

ring 

 

 

6,7,8 NC - 

 

RJ-45

 

1

 

8

 

 

Содержание SA-PAM-SAN-ETH

Страница 1: ...OHS SA PAM SAN ETH 4W SA PAM SAN ETH FXO SA PAM SAN ETH FXS SA PAM SRL ETH SA PAM SRL ETH 4W SA PAM SRL ETH FXO SA PAM SRL ETH FXS G SHDSL Modem USER MANUAL Version 2 0 Revision 18 September 2005 Docu...

Страница 2: ...t 2005 by S Access GmbH The contents of this publication may not be reproduced in any part or as a whole transcribed stored in a retrieval system translated into any language or transmitted in any for...

Страница 3: ...lone delivery set 14 5 2 The SRL SubRackCard delivery set 14 5 3 Connection rules 14 5 4 Communication parameters of the terminal configuration 14 6 THE COMMAND SYSTEM 16 6 1 Basic rules 16 6 2 The ma...

Страница 4: ...zerland WEB www s access ch 8 SNMP 26 8 1 Traps 26 9 TECHNICAL SPECIFICATIONS 27 10 STORAGE CONDITIONS 28 11 CONNECTOR S DESCRIPTION 29 11 1 DSL Connector 29 11 2 DSL Connector for SRL units 29 11 3 M...

Страница 5: ...ementation of SRL models 1 3 07 7 2004 Added Connecter drawing 8 2 Manual corresponding to software version 1 8 Small Text changes 1 4 11 2 2005 Manual corresponding to software version 1 9s SNMP topi...

Страница 6: ...ct s access ch Switzerland WEB www s access ch EU Directive 2002 96 EC and EN50419 This equipment is marked with the above recycling symbol It means that at the end of the life of the equipment you mu...

Страница 7: ...s Line rate in the range from 144 Kbit s to 4624 Kbit s 4W models only Manual or automatic mode of line speed adjustment Ethernet 10 100Base T interface Full Half duplex Transmission of VLAN packet I...

Страница 8: ...M SAN Eth 4W Modem S Access Discovery Tabletop G shdsl 2 pairs up to 4 6Mbps 10 100Base T Bridge VLAN Adapter 230 Vac SA PAM SRL Eth 4W Modem S Access Discovery SubRack G shdsl 2 pairs up to 4 6Mbps 1...

Страница 9: ...re In this case the modem is out of order and should be submitted to the service center for being repaired red informs the user about an urgent alarm An abruption of the connection the correspondence...

Страница 10: ...t link established If the unit is a FXO or FXS model then the LED indicates the following status of Line2 off Telephone line inactive red Telephone line active FXO unit PORT1 green Telephone line acti...

Страница 11: ...dem to the 220 V power supply is implemented using an external power supply unit the Monitor connector to control the modem and store statistics HUB connector to connect the modem to the LAN using a s...

Страница 12: ...Eth User Manual S Access GmbH Tel 41 44 700 31 11 Oberhausenstrasse 47 Page 12 of 32 Fax 41 44 700 31 03 8907 Wettswil a A Email contact s access ch Switzerland WEB www s access ch 4 4 Exterior design...

Страница 13: ...ed informs the user about an urgent alarm An abruption of the connection the correspondence of the signal to noise ratio which does not allow to transmit information and a great number of errored bloc...

Страница 14: ...es connect the modem using the straight Patch Cord cable to the hub through the HUB connector or to the PC through the PC connector Only one device can be connected to modem jack at same time connect...

Страница 15: ...enu will appear on the screen Input Password Please enter your programmed password The unit will be delivered without a password if there is a password default password admin After entering the passwo...

Страница 16: ...lable value of parameters The Esc key is using for canceling of new value of parameters or returning to up menu screen 6 2 The main menu The main menu is the following Discovery G SHDSL Ethernet Monit...

Страница 17: ...atus 7 HDLC Status Select item number or ESC to Upper level menu 6 3 1 Loop Status submenu Upon activation of the performance management submenu the following message will be displayed Performance Man...

Страница 18: ...ch 6 3 2 Ethernet Status submenu Upon activation of the performance management submenu the following message will be displayed Performance Management EtherNet Status Link Link down Link Speed Link Dup...

Страница 19: ...0 HDLC Drop Cnt 0 HDLC Drop Cnt 0 HDLC RxErr Cnt 0 HDLC RxErr Cnt 0 SEGD 0 SEGD 0 Queue 0 Queue 0 1 Clear Counter s Select item number or ESC to Upper level menu 6 4 Configuration management submenu U...

Страница 20: ...Connection Speed 2312K 36N 6 Loop 1 Annex A B 7 Loop 1 Tx Level Adjustment 0 dB 19 2W 4W 2W Select item number or ESC to Upper level menu 6 4 1 1 Operation Mode In this menu you can setup the unit to...

Страница 21: ...kbps for 2wire units and 528 kbps to 4624 kbps for 4wire models 6 4 1 5 Annex With the Appendix menu you can choose between A B A B If you don t know what Annex you have to setup then use the A B conf...

Страница 22: ...in item 19 2W 4W 1 1 Configuration Management DSL Setup 1 Loop 1 Operation Mode Slave 2 Loop 1 Auto Fixed Fixed 3 Loop 1 Clock Source INT 5 Loop 1 Fixed Connection Speed 1160K 18N 6 Loop 1 Annex B 7...

Страница 23: ...e following states Half Full or Auto Disable Mac Filter prohibition of filtration of received packets from Ethernet port side When you set this parameter as Yes all receiving packets on the Ethernet p...

Страница 24: ...nition of connection s passivity Management VLAN enable disable the VLAN packet support for the management of modems VLAN ID The VLAN ID for the VLAN modem management support VLAN Priority This field...

Страница 25: ...Enter the Profile Submenu and Save the settings to Profile 0 Restart the unit 7 2 PC Software download Unzip the download file to an empty directory If necessary rename the actual bin file to all bin...

Страница 26: ...907 Wettswil a A Email contact s access ch Switzerland WEB www s access ch 8 SNMP 8 1 Traps The unit supports the following traps Trap Description Cold start Sent on unit startup Linkup Sent on DSL li...

Страница 27: ...line quality 0 4 mm approx 8 2 km 3 6 km 0 9 mm approx 31 km 13 7 km Line code G shdsl TC PAM Input impedance of the physical line 135 Ohm Output signal level 0 5dBm 15 5 dBm Transmission spectrum fr...

Страница 28: ...essure of 12 kPa 90 Torr at 50 The packed equipment of the S Access family can be stored within 12 months from the date of transshipment including transporting time in storage rooms without heating at...

Страница 29: ...www s access ch 11 CONNECTOR S DESCRIPTION 11 1 DSL Connector Type RJ 45 8 pin Number Signal Assignment 1 2 NC 3 LB a tip 4W model only 4 LA a tip 5 LA b ring 6 LB b ring 4W model only 7 8 NC RJ 45 1...

Страница 30: ...and WEB www s access ch 11 3 Monitor Connector Type Sub D9 female Number Signal Assignment 1 NC 2 TXD Transmit data 3 RXD Receive data 4 DTR Data terminal ready 5 SGND Signal ground 6 NC 7 NC 8 NC 9 N...

Страница 31: ...31 11 Oberhausenstrasse 47 Page 31 of 32 Fax 41 44 700 31 03 8907 Wettswil a A Email contact s access ch Switzerland WEB www s access ch 11 5 Line1 and Line2 Connector Type RJ 11 4 pin Number Signal...

Страница 32: ...ess ch 12 DESCRIPTION OF INTERFACE CABLES 12 1 Ethernet cable Side Color of wire Side B 1 white green 1 2 green white 2 3 white orange 3 4 blue white 4 5 white blue 5 6 orange white 6 7 white brown 7...

Отзывы: