PREDADOOR—TWO-SPEED DIGITAL GATEWAY (E4900)

WIRING SCHEMATICS—PREDADOOR—TWO-SPEED DIGITAL GATEWAY (E4900)

A7500148

NOTE: This schematic is for general infor-

mation only. Due to varying require-
ments for individual customers, a
schematic is prepared for each door
installation. This schematic is
shipped inside of the control box and
must be used for that specific instal-
lation.

LSB*

WITH POWER ON AND NOTHING

CONTACT WILL BE CLOSED.

IN THE LIGHT BEAM, PE2 RELAY

CONTACT WILL BE CLOSED.

WITH POWER ON AND NOTHING
IN THE LIGHT BEAM, PE1 RELAY

1

22

21

24 VAC

BROWN

YLW

24V NEUTRAL

LIGHT ON MODE

26

BLK

BLUE

20

19

18

17

16

15

14

24 VAC

1

BROWN

1

YLW

M1O

M1C

PHOTOEYE PE1*

LIGHT ON MODE

 24V NEUTRAL

PHOTOEYE PE2*

BLK

BLUE

28

27

31 12VDC GND

30

29 +12VDC

27

150 ma

MAX

X2

13

X2

13

MB

ZNR

MB

M1C

M1O

T2

T3

T1

OLRL

T5

T6

T4

OLRH

B2

B3

B1

11

13

12

10

9

8

7

6

5

4

2

3

DG-1200

MOT DET/LOOP

PE2*

PE1*

26

LINE 22

TO SMARTEDGE

OLRL

OLRH

18

17

14

PROG3=PHOTO AC

INPUT 26 SET TO

26

NOTE:

23

CHANGED TO

INPUT 15 LOGIC

NORMALLY OPEN

18

17

14

NOTE:

OPEN/CLOSE

PULL CORD/PB

LSC*

PB1

12

11

9

LSO*

1

8

1

DIGITAL GATEWAY

12

11

9

7

6

6

8

CONNECTED

INTERNALLY

1

4

5

5

2

3

X2

BY OTHERS

SEE MOTOR TABLE
FOR FUSE SIZE

1

FUSED DISCONNECT

L2

L3

L1

* BY RYTEC

5, 18

CLOSE
4, 19

M1O

M1C

OLRL

M1C

M1O

OLRH

OPEN

MOTOR

LO

MOTOR

HI

BRAKE

MOTOR

X2

4

5

3 24 VAC

1

WITH

EDGE CONNECTED

DG17

SMARTEDGE

24V NEUT 2

SMARTEDGE

9

CONTROL

35

34

1

SIGNAL AT 1

EDGE

SE1

PHOTOEYE PE2

MOTOR BRAKE

PHOTOEYE PE1

- FLOOR LOOP

BEIGE

T1

MOTOR

MOTOR

HI

LO

MOTOR

T5

B2

B1

T6

T4

T2

T3

G

FUSED DISCONNECT

T1

T4

T6

B1

B2

T5

T2

T3

BY OTHERS

GND

L1

L3

L2

GND

GREEN/YELLOW

- GROUND

FIELD WIRING

BY OTHERS

- AC CONTROL
- DC CONTROL

TERMINAL BLOCKS

RED
BLUE

BLACK

- POWER

33

SMARTEDGE

34

35

MODULE

CONTROL

SMARTEDGE

4

5

SE1

PE1

LSO

LSC

LSB

PE1/PE2

BLUE

BRN

PE2

26

27

8

9

X2

1

PULL CORD/PB

MOT DET/LOOP

X2

26

8

12

14

9

27

32

1

1

1

X2

0-011-591/0-011-591

0-011-592/0-011-592

0-011-592/0-011-592

RYTEC NO

0-011-591/0-011-591

RECOMMENDED FUSE

0.5/1.0 HP, 850/1750 RPM, 1.15 SF

3 AMP

2.5 AMP

6 AMP

6 AMP

MOTOR DATA

VOLTAGE

575

230

460

208

3.2/3.4

1.6/1.7

1.3/1.4

FLA

3.6/3.8

193-A1D1/193-A1D1

193-A1D1/193-A1D1

193-A1E1/193-A1E1

193-A1E1/193-A1E1

OVERLOAD

BRAKE

B3

B3

1

1

FLOOR
LOOP

LOOP DC

WHITE

BLUE

BLACK

LOOP DETECTOR

12VDC GND

+ 12VDC

IN FLOOR

TO LOOP

TWISTED PAIR

32

33

LP-32DG

GRY

BRN

LOOP

GREEN

DETECTOR

X2

FU1

X1

CT1

24 VAC

H1

FU2

100 VA

X2

FU2

1

H3

H2

H4

460V -

H2-H3

230V -

H2-H4

H1-H3

Содержание DG1200

Страница 1: ...Revision April 15 1998 0 215 006 Rytec Corporation Digital Gateway Installation Owners Manual Model DG1200...

Страница 2: ......

Страница 3: ...NPUTS TOTHE DIGITAL GATEWAY AC INPUTS 4 Limit Switches Terminals 8 and 9 4 OPEN LSO 4 CLOSE LSC 4 PB1 Pushbutton Terminal 11 4 Alternate Action Inputs A A Momentary Contact Activators Terminal 12 4 Au...

Страница 4: ...UP PROCEDURES 8 ALARM CONDITIONS COnnECt MISSING CONNECTIONS 9 OP 0 OPEN TIME EXCEEDED 9 CL 0 CLOSE TIME EXCEEDED 10 AJAr BREAKAWAY KILL SWITCH 10 OLr OVERLOAD RELAY 10 EdGE REVERSING EDGE 10 NON ALA...

Страница 5: ...assage Limit Switch LSP 14 PROGRAM 4 PROGRAMMABLE OPTIONS 15 Close Jog 15 Open Jog 15 Reverse Delay 15 Loop Call Delay 15 PROGRAM 5 REVERSE INPUT LOGIC 15 PROGRAM 6 15 SETTING THE PROGRAM OPTIONS 15 D...

Страница 6: ...This page intentionally left blank...

Страница 7: ...oten tial for personal injury if the procedure is not performed as described CAUTION is used to indicate the potential for damage to the product or property dam age if the procedure is not followed as...

Страница 8: ...r an overview of the Digital Gateway controls A0500028 DOWN Arrow Auto Close Delay Timer A A Close Delay Timer UP Arrow Display Message Explanation CLOSE Backup Timer OPEN Backup Timer Digital Display...

Страница 9: ...button will operate while the Digital Gateway is in the AJAr or EdGE alarm condition See Figure 1 CLOSE JOG This pushbutton jogs the door closed It is not operational when the door is being controlled...

Страница 10: ...rnate Action Inputs A A Momentary Contact Activators Terminal 12 N O Contact A momentary connection while the door is closed closing or stopped between limits will open the door A momentary connection...

Страница 11: ...Conditions It will reset the system the same as the Open Jog Reset button Program 2 Terminal 24 N O Contact This input has various functions that are explained in the Programming section of this manu...

Страница 12: ...closed closing or stopped between limits The door will remain open as long as the connection is present When the connection is removed the Auto Close delay timer will count down and close the door Th...

Страница 13: ...be displayed as OP plus time CLOSE BACKUPTIMER This is the backup timer for the closing of the door It functions the same as the open backup timer When the time has been exceeded the CL 0 message will...

Страница 14: ...kup Timer A0500027 Figure 7 START UP PROCEDURES 1 Install the door following the procedures outlined in the door installation manual 2 Make all necessary electrical connections Follow the electrical s...

Страница 15: ...s must be present If neither of the limit connections are present both the LSO and LSC LEDs will blink If the limits are wired correctly and the Digital Gateway still shows a missing limit connection...

Страница 16: ...box has tripped The display message OLr will blink and the OLR LED will be on Find and correct the problem that caused the overload relay to trip reset the overload relay and reset the Digital Gatewa...

Страница 17: ...ateway is reset with the Open Jog Reset button or Stop input See Figure 14 HELLO A0500027 Figure 14 EdGE REVERSING EDGETRIPPED The message EdGE will be displayed if the door comes down on something ac...

Страница 18: ...puts of the Digital Gateway share a common power source which is terminal 4 Terminal 4 is internally connected to the 24 vac power source Terminal 5 is the open output supplying power to the open cont...

Страница 19: ...ilable program follows See SETTING THE PROGRAM OPTIONS on page 15 for programming instructions PROGRAM 1 OUTPUT 7 This output can tell you if the door is not closed fully open or about to close When o...

Страница 20: ...r is fully closed the door will open and the Passage timer PEt will begin counting down When the Passage timer reaches zero the door will stop Activating this input again will close the door If the A...

Страница 21: ...on the loop long enough to open the door but traffic approaching the door will activate the door When the Loop input is activated while the door is fully closed the Loop timer will count down and then...

Страница 22: ...e digits of the security code then press the Set button to enter the Program Mode 3 Once you have entered the program mode the display will show the various program menus See Figure 21 Press the Selec...

Страница 23: ...with a normally open N O or a normally closed N C contact connected to them See PROGRAM 5 REVERSE INPUT LOGIC on page 15 The various models of Rytec doors require slightly different combinations of N...

Страница 24: ...93 A1D1 193 A1D1 193 A1C1 MOTOR DATA 230 208 VOLTAGE 460 575 2 9 FLA 1 8 0 97 0 7 150 ma MAX 20 21 23 26 4 28 29 27 30 5 OPEN CLOSE 4 M1C M1O OLR X2 2 3 1 4 CONNECTED INTERNALLY DIGITAL GATEWAY LSO 5...

Страница 25: ...al infor mation only Due to varying require ments for individual customers a schematic is prepared for each door installation This schematic is shipped inside of the control box and must be used for t...

Страница 26: ...8 CONNECTED INTERNALLY 1 4 5 5 2 3 X2 BY OTHERS SEE MOTOR TABLE FOR FUSE SIZE 1 FUSED DISCONNECT L2 L3 L1 BY RYTEC 5 18 CLOSE 4 19 M1O M1C OLRL M1C M1O OLRH OPEN MOTOR LO MOTOR HI BRAKE MOTOR X2 4 5...

Отзывы: