PROGRAM 4, PROGRAMMABLE OPTIONS

This program section allows you to change the Open
and Close inputs to constant pressure/jog, set a
reverse delay timer and/or a loop call delay. More than
one of these options can be on at the same time.

Close Jog, CLJ = On/CLJ = OFF

This option converts the Close Input (input 21) to
constant pressure/jog operation. The door will only
close while the input is activated.

Open Jog, OPJ = On/OPJ = OFF

This option converts the Open Input (input 20) to
constant pressure/jog operation. The door will only
open while the input is activated.

Reverse Delay, rdt = 00

The Digital Gateway is programmed to immediately
reverse the door if an activator or safety input is
operated while the door is closing. This option can be
used to delay the reversal of the door. If the A/A, Auto
or Open input is activated while the door is closing the
reversal will be delayed by the time set on the Re-
verse Delay timer. The door will stop, the Reverse
Delay timer (rdt) will time out and the door will then
open. Reversals due to the photoeye or reversing
edge inputs will not be delayed.

The maximum setting is 15 seconds. The factory
default setting is 0 which disables the timer.

Loop Call Delay, LPt = 00

This option will delay the opening of the door when it
is opened by the Loop input. This can be used for
cross traffic situations. Traffic crossing in front of the
door will not remain on the loop long enough to open
the door but traffic approaching the door will activate
the door.

When the Loop input is activated while the door is
fully closed the Loop timer will count down and then
open the door. If the Loop input returns to the normal
inactivated state while the timer is counting down the
door will not open and the system will return to the
normal state.

If the Loop input is activated while the door is closing
the door will immediately reverse to the fully open
position.

The maximum setting is 15 seconds. The factory
default setting is 0 seconds which disables the timer.

PROGRAM 5, REVERSE INPUT LOGIC

This option can be used to reverse the required logic
for some of the inputs. The required contact arrange-
ment can be changed from normally closed (N.C.) to
normally open (N.O.). The inputs that can be changed
are Open Limit (LSO - #8), Close Limit (LSC - #9),
Photoeye—DC (Pdc - #15), Reversing Edge (rE- #17),
Stop (StP - #23), Program 3 (PG3 - #26) and Break-
away Limit (LSb - #27).

PROGRAM 6

This program option is set for factory use. It requires
an additional three digit security code. If you find
yourself in Program 6, press the Set button to return
to the main menu.

SETTING THE PROGRAM OPTIONS

As described in the OPTIONAL PROGRAMS section,
there are 6 program menus and their submenus
available. You will use the UP and DOWN arrows, the
Set button (A/A Close Delay) and the Select button
(Auto Close Delay) to select and set the program
options which will be shown on the display. (See
Figure 19.)

A0500027

UP Arrow

DOWN
Arrow

Display

Select Button

Set Button

Figure 19

SETTING THE  PROGRAM  OPTIONS

Содержание DG1200

Страница 1: ...Revision April 15 1998 0 215 006 Rytec Corporation Digital Gateway Installation Owners Manual Model DG1200...

Страница 2: ......

Страница 3: ...NPUTS TOTHE DIGITAL GATEWAY AC INPUTS 4 Limit Switches Terminals 8 and 9 4 OPEN LSO 4 CLOSE LSC 4 PB1 Pushbutton Terminal 11 4 Alternate Action Inputs A A Momentary Contact Activators Terminal 12 4 Au...

Страница 4: ...UP PROCEDURES 8 ALARM CONDITIONS COnnECt MISSING CONNECTIONS 9 OP 0 OPEN TIME EXCEEDED 9 CL 0 CLOSE TIME EXCEEDED 10 AJAr BREAKAWAY KILL SWITCH 10 OLr OVERLOAD RELAY 10 EdGE REVERSING EDGE 10 NON ALA...

Страница 5: ...assage Limit Switch LSP 14 PROGRAM 4 PROGRAMMABLE OPTIONS 15 Close Jog 15 Open Jog 15 Reverse Delay 15 Loop Call Delay 15 PROGRAM 5 REVERSE INPUT LOGIC 15 PROGRAM 6 15 SETTING THE PROGRAM OPTIONS 15 D...

Страница 6: ...This page intentionally left blank...

Страница 7: ...oten tial for personal injury if the procedure is not performed as described CAUTION is used to indicate the potential for damage to the product or property dam age if the procedure is not followed as...

Страница 8: ...r an overview of the Digital Gateway controls A0500028 DOWN Arrow Auto Close Delay Timer A A Close Delay Timer UP Arrow Display Message Explanation CLOSE Backup Timer OPEN Backup Timer Digital Display...

Страница 9: ...button will operate while the Digital Gateway is in the AJAr or EdGE alarm condition See Figure 1 CLOSE JOG This pushbutton jogs the door closed It is not operational when the door is being controlled...

Страница 10: ...rnate Action Inputs A A Momentary Contact Activators Terminal 12 N O Contact A momentary connection while the door is closed closing or stopped between limits will open the door A momentary connection...

Страница 11: ...Conditions It will reset the system the same as the Open Jog Reset button Program 2 Terminal 24 N O Contact This input has various functions that are explained in the Programming section of this manu...

Страница 12: ...closed closing or stopped between limits The door will remain open as long as the connection is present When the connection is removed the Auto Close delay timer will count down and close the door Th...

Страница 13: ...be displayed as OP plus time CLOSE BACKUPTIMER This is the backup timer for the closing of the door It functions the same as the open backup timer When the time has been exceeded the CL 0 message will...

Страница 14: ...kup Timer A0500027 Figure 7 START UP PROCEDURES 1 Install the door following the procedures outlined in the door installation manual 2 Make all necessary electrical connections Follow the electrical s...

Страница 15: ...s must be present If neither of the limit connections are present both the LSO and LSC LEDs will blink If the limits are wired correctly and the Digital Gateway still shows a missing limit connection...

Страница 16: ...box has tripped The display message OLr will blink and the OLR LED will be on Find and correct the problem that caused the overload relay to trip reset the overload relay and reset the Digital Gatewa...

Страница 17: ...ateway is reset with the Open Jog Reset button or Stop input See Figure 14 HELLO A0500027 Figure 14 EdGE REVERSING EDGETRIPPED The message EdGE will be displayed if the door comes down on something ac...

Страница 18: ...puts of the Digital Gateway share a common power source which is terminal 4 Terminal 4 is internally connected to the 24 vac power source Terminal 5 is the open output supplying power to the open cont...

Страница 19: ...ilable program follows See SETTING THE PROGRAM OPTIONS on page 15 for programming instructions PROGRAM 1 OUTPUT 7 This output can tell you if the door is not closed fully open or about to close When o...

Страница 20: ...r is fully closed the door will open and the Passage timer PEt will begin counting down When the Passage timer reaches zero the door will stop Activating this input again will close the door If the A...

Страница 21: ...on the loop long enough to open the door but traffic approaching the door will activate the door When the Loop input is activated while the door is fully closed the Loop timer will count down and then...

Страница 22: ...e digits of the security code then press the Set button to enter the Program Mode 3 Once you have entered the program mode the display will show the various program menus See Figure 21 Press the Selec...

Страница 23: ...with a normally open N O or a normally closed N C contact connected to them See PROGRAM 5 REVERSE INPUT LOGIC on page 15 The various models of Rytec doors require slightly different combinations of N...

Страница 24: ...93 A1D1 193 A1D1 193 A1C1 MOTOR DATA 230 208 VOLTAGE 460 575 2 9 FLA 1 8 0 97 0 7 150 ma MAX 20 21 23 26 4 28 29 27 30 5 OPEN CLOSE 4 M1C M1O OLR X2 2 3 1 4 CONNECTED INTERNALLY DIGITAL GATEWAY LSO 5...

Страница 25: ...al infor mation only Due to varying require ments for individual customers a schematic is prepared for each door installation This schematic is shipped inside of the control box and must be used for t...

Страница 26: ...8 CONNECTED INTERNALLY 1 4 5 5 2 3 X2 BY OTHERS SEE MOTOR TABLE FOR FUSE SIZE 1 FUSED DISCONNECT L2 L3 L1 BY RYTEC 5 18 CLOSE 4 19 M1O M1C OLRL M1C M1O OLRH OPEN MOTOR LO MOTOR HI BRAKE MOTOR X2 4 5...

Отзывы: