15
PROGRAM 4, PROGRAMMABLE OPTIONS
This program section allows you to change the Open
and Close inputs to constant pressure/jog, set a
reverse delay timer and/or a loop call delay. More than
one of these options can be on at the same time.
Close Jog, CLJ = On/CLJ = OFF
This option converts the Close Input (input 21) to
constant pressure/jog operation. The door will only
close while the input is activated.
Open Jog, OPJ = On/OPJ = OFF
This option converts the Open Input (input 20) to
constant pressure/jog operation. The door will only
open while the input is activated.
Reverse Delay, rdt = 00
The Digital Gateway is programmed to immediately
reverse the door if an activator or safety input is
operated while the door is closing. This option can be
used to delay the reversal of the door. If the A/A, Auto
or Open input is activated while the door is closing the
reversal will be delayed by the time set on the Re-
verse Delay timer. The door will stop, the Reverse
Delay timer (rdt) will time out and the door will then
open. Reversals due to the photoeye or reversing
edge inputs will not be delayed.
The maximum setting is 15 seconds. The factory
default setting is 0 which disables the timer.
Loop Call Delay, LPt = 00
This option will delay the opening of the door when it
is opened by the Loop input. This can be used for
cross traffic situations. Traffic crossing in front of the
door will not remain on the loop long enough to open
the door but traffic approaching the door will activate
the door.
When the Loop input is activated while the door is
fully closed the Loop timer will count down and then
open the door. If the Loop input returns to the normal
inactivated state while the timer is counting down the
door will not open and the system will return to the
normal state.
If the Loop input is activated while the door is closing
the door will immediately reverse to the fully open
position.
The maximum setting is 15 seconds. The factory
default setting is 0 seconds which disables the timer.
PROGRAM 5, REVERSE INPUT LOGIC
This option can be used to reverse the required logic
for some of the inputs. The required contact arrange-
ment can be changed from normally closed (N.C.) to
normally open (N.O.). The inputs that can be changed
are Open Limit (LSO - #8), Close Limit (LSC - #9),
Photoeye—DC (Pdc - #15), Reversing Edge (rE- #17),
Stop (StP - #23), Program 3 (PG3 - #26) and Break-
away Limit (LSb - #27).
PROGRAM 6
This program option is set for factory use. It requires
an additional three digit security code. If you find
yourself in Program 6, press the Set button to return
to the main menu.
SETTING THE PROGRAM OPTIONS
As described in the OPTIONAL PROGRAMS section,
there are 6 program menus and their submenus
available. You will use the UP and DOWN arrows, the
Set button (A/A Close Delay) and the Select button
(Auto Close Delay) to select and set the program
options which will be shown on the display. (See
Figure 19.)
A0500027
UP Arrow
DOWN
Arrow
Display
Select Button
Set Button
Figure 19
SETTING THE PROGRAM OPTIONS
Содержание DG1200