17
6.
For the remaining programs use the Select button
to scroll through the options. Use the UP and
DOWN arrow keys to set the time or option and
the Set button to return to the Main Program
menu after all the selections are made.
7.
When a timer is associated with an option, the
display will show the code for the option and the
timer setting. Use the UP and DOWN arrow keys
to set the timers. Figure 23 shows the Delay To
Close timer set to 0 seconds. Use the Set button
to return to the Main Program menu.
A0500027
dtc = 00
Figure 23
8.
When all options have been selected, press the
Open and Close Backup Timer buttons to leave
the program mode. The Digital Gateway is then
ready for operation.
DEFAULT INPUT SETTING
DEFAULT INPUT SETTING
A number of the inputs on the Digital Gateway can be
set to operate with a normally open (N.O.) or a
normally closed (N.C.) contact connected to them.
(See PROGRAM 5, REVERSE INPUT LOGIC on
page 15.) The various models of Rytec doors require
slightly different combinations of N.O. and N.C.
contacts. The following defaults can be used to set up
the Digital Gateway inputs for standard doors:
FAST-SEAL DOOR
To set this default, press and hold the A/A Close
Delay/Set button, turn the power off and on. Release
the button.
This default will set LSO (N.C.), LSC (N.C.), PdC
(N.C.), rE (N.C.), Stp (N.C.), PG3 (N.O.) and LsB
(N.C.).
FAST-FOLD DOOR
To set this default, press and hold the Auto Close
Delay/Select button, turn the power off and on.
Release the button.
This default will set LSO (N.C.), LSC (N.C.), PdC
(N.O.), rE (N.O.), StP (N.C.), PG3 (N.O.) and LsB
(N.O.).
PREDADOOR/TURBO-SEAL DOOR
To set this default, press and hold the Open Backup
Timer button, turn the power off and on. Release the
button.
This default will set LSO (N.C.), LSC (N.C.), PdC
(N.O.), rE (N.C.), StP (N.C.), PG3 (N.C.) and LsB
(N.C.).
Set the timers and other program options as required.