26 Basic
service
Basic service
Before servicing the RUSH Club Smoke Dual™, read and observe all the
precautions listed in “Safety information” on page 5. Any service not
described in this section must be carried out by a Martin service technician.
To find your local Martin service centre visit www.martin.com
Cleani ng
Excessive dust, fog fluid, and dirt build-up will degrade performance and cause
overheating and damage to the system that is not covered by the product
warranty. To maintain adequate cooling, dust must be cleaned from the outer
casing and air vents of the system periodically.
Isolate the system from power and allow to cool completely before cleaning.
The fog/haze output nozzles remain hot for a period after use.
•
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
•
Clean fog fluid residues from the fog output of the system using a damp
cloth.
•
Clean the outer casing with a damp cloth only.
Fuse replacement
The fuses for the system are located on the electronics board inside the units.
DANGER! Disconnect the power supply before removing any covers. Live
parts inside!
To replace a fuse, disconnect the power cord from the supply, unscrew the
screws holding the top cover of the unit and remove the cover. The electronics
board is located in the compartment under the display.
Remove the spent fuse and replace with one of exactly the same size and rating.
The fuse type is indicated below. Contact Martin Service if the fuse blows
repeatedly.
Fog head
120 V = 10 AT
230 V = 6.3 AT
Haze head
120 V = 10 AT
230 V = 6.3 AT
Pump unit
120 V = 3.15 AT
230 V = 3.15 AT