12 Quick
Start
Quick Start
You are no doubt eager to switch on the system and try it out by making a lot of
fog. This section tells you how to do that. However, please also make the time to
read the safety and servicing instructions in the remainder of this manual.
Setting up
Locate the head(s) in a suitably large area with nothing in front of the fog output.
Connect the fluid pipes from the head units to the base unit. A maximum of 2
heads of the same type (fog or haze) can be connected to each output on the
base unit. If you are connecting 2 heads, use a T-connector to link the pipes.
Connect the heads to the base unit with RJ45 cables. If you are connecting 2
heads to an output, the second head is linked from the first.
Fill the fluid tank in the base unit with RUSH Club Smoke Dual Fluid™ only.
Use
of other fluid will void the warranty.
Connect a suitably rated power supply to the heads and to the base unit using
the supplied IEC cable. The power requirements are:
Base unit
0.9 A @ 230 V (EU model)
1.7 A@ 120 V (US model)
Fog Heads
5.1 A @ 230 V (EU model)
8.6 A @ 120 V (US model)
Haze Heads
4.0 A @ 230 V (EU model)
7.6 A @ 120 V (US model)
Now set the mains switches, on the rear of each head and on the top of the base
unit, to the ‘ON’ position. The display will show HEAT. If the display shows OFF
use the menu panel to set the RUNF option to CONT. After about 6-8 minutes the
display should show CONT and the system will begin producing fog. If the
display shows RDY use the menu panel to set the RUNF option to CONT to start
fog.
Once the system has heated the first time you will need to prime the pipework
using the 4 prime buttons at the bottom of the control panel.
Making fog and haze
If you want to adjust the fog density manually, press the Menu < > buttons until
the display shows FOG, then press the Enter button and use the Value up/down
buttons to select a value above 0%. The Haze density can be adjusted using the
HAZE menu the same way.
You can also adjust the fan speed using the FAN menu.
If no fog is produced it may be necessary to prime the system,
press the Menu <> buttons until the display shows PRME, then
press the Value Up button so the display shows Y, then press the
Enter button.