Installation and setting up
13
Installation and setting up
DANGER! DO NOT operate the system until you have read and observed all the
precautions listed under “Safety information” on page 5.
Locatio n
The RUSH Club Smoke Dual™ heads are designed to be located on the floor or
may be suspended using the fitted flying bracket. The heads can operate in any
orientation from vertically down to vertically up. They must not be used upside
down.
If the heads are to be suspended, ensure the mounting surface can support the
weight of the head. Do not suspend the heads over areas where people will be
underneath. Use only the fitted flying bracket to suspend the head.
Ensure that there is at least 100mm clearance all-round the head and at least
60cm in front of the fog output.
The base pump unit can be located in any convenient location, but must be
within 10m of the furthest haze head or 50m of the furthest fog head. It must be
the lowest point of the system and not more than 10m below the highest head.
Keep 150mm clearance around the unit and 300mm above the unit.
AC power
Before using the system, ensure that a grounding-type (earthed) power plug that
fits the local power outlets is installed on the IEC cable provided and on the
mains cable of each head.
DANGER! Make sure the power plug is correctly rated:
• For EU (230 V) use fit a plug rated 6 amps minimum
• For US (120 V) use fit a plug rated 10 amps minimum
When installing the plug, follow the plug manufacturer’s instructions and connect
pins as follows:
Yellow and green wire to ground (earth), blue wire to neutral and brown wire to
live.
The table below shows some common pin identification schemes.
wire function
marking
screw
colour
brown live
“L”
yellow
or
brass
blue neutral
“N” silver
green/yellow earth
green