user manual 

 
 
 
 
 
 
 

 

P/N 35010041-B

 

READ AND SAVE THESE INSTRUCTIONS

Содержание Club smoke dual

Страница 1: ...user manual P N 35010041 B READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...2 Dimensions Dimensions All dimensions are in millimeters...

Страница 3: ...y the use of inability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this d...

Страница 4: ...nsity for Fog heads 17 Setting Haze Run modes 17 Setting output density for Haze heads 18 Setting the Timer 18 Setting the DMX base address 18 Setting the master slave link mode 18 Priming the system...

Страница 5: ...in this manual and the system is malfunctioning please contact Martin Service Preventing electric shocks Always ground earth the system electrically Use only a source of AC power that complies with lo...

Страница 6: ...ic effects Do not attempt to bypass thermostatic switches fluid sensors or fuses Replace fuses only with ones of the type and rating specified in this manual for the system Provide a minimum free spac...

Страница 7: ...s swallowed give water and obtain medical advice This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and kno...

Страница 8: ...using a simple push together fluid line and a single control cable Congratulations on your purchase of the RUSH Club Smoke Dual from Martin Details of the full range of Martin products are available...

Страница 9: ...m pump unit Mains power switch Mains inlet cable Fluid pipe connection Heat red and Ready green indicators Product details Fog Head Fog output nozzle WARNING High temperature vapour and surfaces If su...

Страница 10: ...om pump unit Mains power switch Mains inlet cable Fluid pipe connection Heat red and Ready green indicators Haze fan inlet Haze Head Haze output port WARNING High temperature vapour and surfaces If su...

Страница 11: ...onnector Main power switch Digital remote plug AVR program upload socket and status LEDs 5 pin DMX input and link 3 pin DMX input and link Hinged door to fluid tank compartment Control connections to...

Страница 12: ...V EU model 1 7 A 120 V US model Fog Heads 5 1 A 230 V EU model 8 6 A 120 V US model Haze Heads 4 0 A 230 V EU model 7 6 A 120 V US model Now set the mains switches on the rear of each head and on the...

Страница 13: ...ump unit can be located in any convenient location but must be within 10m of the furthest haze head or 50m of the furthest fog head It must be the lowest point of the system and not more than 10m belo...

Страница 14: ...y with Martin RUSH Club Smoke Dual Fluid see page 25 Up to two heads of the same type fog or haze may be connected to each fluid output of the pump unit Push the fluid tubing into the connections on t...

Страница 15: ...Installation and setting up 15 Connection of two heads on one channel Connection of fully loaded system T connector Haze heads on channel 1 T connector...

Страница 16: ...on the base unit located next to the power inlet The display will show HEAT If the display shows OFF go to the RUNF menu on the digital control panel and set the option to CONT The system will rememb...

Страница 17: ...e the setting The display shows Selecting OFF will disable the heaters on the unit Setting output density for Fog heads Use the Menu Previous Next buttons to select the option Use the Up Down buttons...

Страница 18: ...up or down Press the Enter button to store the address setting The system will automatically respond to a DMX controller whenever it is connected When using in a DMX system ensure the LINK menu is se...

Страница 19: ...nd 3 independently This is used to expel air from the pipes between the pump unit and the heads after installation Priming continues while the buttons are held down and stops when the buttons are rele...

Страница 20: ...20 Control settings The factory settings are option setting FOG HAZE TRUN seconds TOFF seconds RUNF RUNH ADDR DISP LINK PRME...

Страница 21: ...UN 0 99 seconds TOFF 0 99 seconds RunF run mode for fog heads RUN OFF STBY TIME CONT RunH run mode for haze heads RUN STBY TIME CONT The functions are the same as on the built in control panel and are...

Страница 22: ...22 Remote control The remote control is powered through its cable by the RUSH Club Smoke Dual no batteries are required The cable may be extended to up to 25 m 82 ft with a 3 pin XLR DMX cable...

Страница 23: ...n or link through but you should not use the unit as a splitter by connecting both the 3 pin and 5 pin outputs For best results use cable designed for high speed digital data transmission Suitable DMX...

Страница 24: ...put 100 Channel 3 DMX value range Function Macro description Default value Fog haze output 3 level 0 12 Idle range None 0 13 240 Output 0 100 241 255 Output 100 Channel 4 DMX value range Function Macr...

Страница 25: ...RUSH Club Smoke Dual fluid 25L To find your local dealer visit www martin com DANGER The RUSH Club Smoke Dual can run safely only on the specific fog fluid it is designed for Use ONLY the Martin fog...

Страница 26: ...ain hot for a period after use Remove dust from the air vents with a soft brush cotton swab vacuum or compressed air Clean fog fluid residues from the fog output of the system using a damp cloth Clean...

Страница 27: ...age 18 Poor connection in DMX line Check DMX cables and connections LINK menu is set to SEND Set LINK menu to RECV All fog haze outputs are weak Base pump unit requires priming Prime base pump unit pa...

Страница 28: ...show the run time The system is in Timer mode and is in an OFF period the number counts down to show the off time Run out of fluid Refill the fluid tank and operate the base prime function bottom righ...

Страница 29: ...with 10L fluid 2 8 hours Fog coverage volume 550m per minute Control and programming Control options Onboard digital control panel DMX optional digital remote control Control options Continuous or tim...

Страница 30: ...head EU model 1150 W 5 1 A Fog head US model 1000 W 8 6 A Haze head EU model 900 W 4 0 A Haze head US model 900 W 7 6 A Base pump unit EU model 180 W 0 9 A Base pump unit US model 180 W 1 7 A Measure...

Страница 31: ...moke Dual EU model 230V P N 92250150 Haze head RUSH Club Smoke Dual US model 120V P N 92250180 Haze head RUSH Club Smoke Dual EU model 230V P N 92250170 Specifications subject to change without notice...

Страница 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...