To enter into instrument setting function, please power on the Instrument first and then press
key.
Under setting mode, the Auxiliary Screen displays set items; the Main Screen shows factory default value. Press
key to alter setting; press
key to save set value (mark SAVE displays in the lower left part, indicating the set
item has been saved)
When selecting the last item, repress
key to exit setting mode.
Setting Items
Function
Default
Value
auto-power-off
Setting range is 0
~
90 minutes, press
key to select blinking position ,
press
key to set flicker bit, press key to set flicker digits; Setting as 0
indicating cancel auto- power- off function.
5 minutes
backlight time
setting
Setting range is 0
~
90 minutes, press
key to select blinking position ,
press
key to set flicker bit, press key to set flicker digits; Setting as 0
indicating cancel auto- power- off function.
5 minutes
earth spike
interval
Setting range is 1.0
~
30.0m, press
key to select blinking position ,
press
key to set flicker bit, press
key to set flicker digits.
10.0m
10.0
meters
beeper
ON or OFF , press
key to select
ON
Back to factory
default setting
Press
key, the Main Screen displays SAVE in the lower left part,
the Instrument return back to default setting.
- - - - -