External Control
70
Lightstyle™ Series LS-100d Installation/Operation Manual
PRE
L
IMINAR
Y
•
y
is the operand, which can have one of the following values:
?
= “Get” operand
+
= “Increment” operand
=
= “Set” operand
-
= “Decrement” operand
•
z
is the value to set for this parameter. It can have one of two formats:
•
Integer value:
Any positive or negative number; for example,
100
.
•
S
tring value:
Any string surrounded by double quotes; for example,
“This is a
string.”
•
[CR]
is the ASCII carriage return key (0x0D).
Response Format
Responses sent from the follower to the initiator shall have the following format:
(u;www:x=z) [CR]
Where:
•
(
and
)
indicate the start and end of the command data. If these characters are
present, the DHD Controller assumes that valid command data is present in the
command string. Otherwise, the DHD Controller ignores the command.
• “u;” indicates the response code. This is only used by followers responding to a valid
CLI command received. For any response code other than 0, the follower echoes back
the command received rather than filling in the fields listed below.
The response code can be one of the following:
• 0 = Command successfully processed
• 1 = Unknown command code
• 2 = Invalid operator
• 3 = Destination parameter not supported
• 4 = Setting not available
• 5 = Setting value not available
• 6 = Setting value not supported
• 7 = String too long
• 8 = Command not supported in standby mode
• 9 = Invalid parameter
• 10 = Error processing command
• 11 = Password not entered
•
www
indicates the command code. This field is case insensitive; for example,
PWR
,
pwr
and
PwR
are all equivalent.
•
:x
is the destination parameter. This is an optional parameter that indicates which
memory the command is referencing. This parameter is reserved for future use.
•
z
is the new value (for Set, Increment or Decrement commands) or the current value
(for Get commands) for this parameter. It can have one of two formats:
•
Integer value:
Any positive or negative number; for example,
100
.
•
S
tring value:
Any string surrounded by double quotes; for example,
“This is a
string.”
•
[CR]
is the ASCII carriage return key (0x0D).
➤
Содержание LightStyle LS-100d
Страница 2: ......
Страница 10: ...x Lightstyle Series LS 100d Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 14: ...Table of Contents xiv Lightstyle Series LS 100d Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 16: ...List of Figures xvi Lightstyle Series LS 100d Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 50: ...Installation 34 Lightstyle Series LS 100d Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 82: ...Operation 66 Lightstyle Series LS 100d Installation Operation Manual P R E L I M I N A R Y Notes...
Страница 105: ...External Control Lightstyle Series LS 100d Installation Operation Manual 89 P R E L I M I N A R Y Notes...
Страница 106: ...External Control 90 Lightstyle Series LS 100d Installation Operation Manual P R E L I M I N A R Y...
Страница 113: ......
Страница 114: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1174 00 Rev A December 2011...