- 6 -
65F-68F
(1 x 40G
mode)
Off
The port is not linked up.
Solid green
Port 40G is linked up.
Blinking green.
Port 40G is transceiving data.
Power Supply
The RG-S6220 series switches support power supply the RG-M6220-AC460E-F. The smart power supply module
supports power management, and the host can read input power, input current, and temperature in real time. The
power supply module supports hot plugging.
The RG-S6220 series switches support power supply 1+1 redundancy. To improve the stability and reliability of
the entire system, it is recommended to configure power supply module 1+1 redundancy. When the two power
supply modules work normally, the switch is in the status of current sharing.
It requires at least one power supply module to work normally. Baffles need to be installed in the empty power
supply module slots to ensure ventilation and heat dissipation and avoid dusts.
Heat Dissipation
The working temperature of the RG-S6220-48XS4QXS V1.XX switches is 0-50
℃
, and the heat dissipation design
needs to ensure the stability, safety and maintainability in such environment. The RG-S6220 series switches adopt fan
ventilation and forced convection to ensure the device can work normally in specified environment. Dust the device
every three months to avoid blocking the ventilation openings.
The RG-S6220-48XS4QXS V1.XX supports fan module M6220-FAN-F and provides fan speed regulation, fan failure
warning, and fan hot plugging.
Figure 1-5 Ventilation and Heat Dissipation of the RG-S6220-48XS4QXS V1.XX
Leave sufficient space in the front and at the back of the chassis (at least 20 cm) for ventilation.
It requires at least three fan modules to work normally. Baffles need to be installed in the empty fan module slots to
ensure ventilation and heat dissipation and avoid dusts.
1.2 RG-S6220-48XS4QXS V2.XX
Specifications
Model
RG-S6220-48XS4QXS V2.XX (XX indicates number)
CPU
Dual-core CPU, each core with the clock speed of 1.0G
BOOT ROM
8MB
Flash Memory
512MB