- 5 -
Solid red
1) One of the modules of the system fails.
2) The internal temperature exceeds the warning
working temperature, and the switching service
resets.
Blinking green.
The system is initializing.
Solid green
The system is working normally.
Solid yellow
The temperature gets to the warning threshold.
Power module 1
indicator
PWR1
Off
The power supply module is not in the position.
Solid yellow
The power supply temperature exceeds the normal
working temperature.
Solid red
The power supply module fails or it is not connected
with the AC power cord.
Solid green
The power supply module works normally.
Power module 2
indicator
PWR2
Off
The power supply module is not in the position.
Solid yellow
The power supply temperature exceeds the normal
working temperature.
Solid red
The power supply module fails or it is not connected
with the AC power cord.
Solid green
The power supply module works normally.
RCMI port indicator
RCMI
Off
The port is not linked up.
Green
The port is linked up in 1000M mode.
Yellow
The port is linked up in 10M or 1000M mode.
Blinking
Data are transceiving at the port.
Cycling blinking
green, yellow and
red.
This status helps to locate the device position.
Fan module indicator
Fan
Solid green
All fan modules are in the position and working
normally.
Solid yellow
Only three fan modules are in the position.
Solid red
1) A fan fails.
2) The number of the fan module is less than three.
SFP+ port status
indicator
1F-8F
(Ethernet
mode)
Off
The port is not linked up.
Solid green
Port 10G/1G is linked up.
Blinking green.
Port 10G/1G is transceiving data.
1F-8F
(FC mode)
Off
The port is not linked up.
Solid yellow
Port2/4/8G is linked up.
Blinking yellow
Port2/4/8G is transceiving data.
9F-48F
(Ethernet
mode)
Off
The port is not linked up.
Solid green
Port 10G/1G is linked up.
Blinking green.
Port 10G/1G is transceiving data.
QSFP+ port status
indicator
49F-64F
(4 x 10G
mode)
Off
The port is not linked up.
Solid green
Port 10G is linked up.
Blinking green.
Port 10G is transceiving data.