background image

 

- 2 - 

Power Supply Input 

AC input 

Rated voltage range: 100 VAC to 240 VAC   

Maximum voltage range: 90 VAC to 264 VAC   

Frequency: 50 Hz to 60 Hz   

Rated current: 5.29 A 

High voltage direct current (HVDC) input: 

Input voltage range: 192 VDC to 290 VDC                                             

Input current range: 2.66 A to 2.03 A 

Power 

Consumption 

Less than 250 W 

Optical Module 

Refer to Appendix B 

 

The supported modules update at any time, contact Ruijie Networks for details. 

SFP+ Port 

Supported 

QSFP+ Port 

Supported 

FC Port 

Port 1 to Port 8 also support SFP+ port. 

10Gbase-T Port 

Unsupported 

Temperature 

Warning 

Support temperature warning and over-temperature protection. 

EMC 

GB9254-2008 CLASSA 

EMI 

GB4943-2011 

Working 

Temperature 

0°C to 50°C 

Storage 

Temperature 

-40°C to 70°C 

Working Humidity 

10% to 90% RH(non-condensing) 

Weight 

Net weight 9KG (including four fan modules and two power modules) 

Dimensions 

440 x 420 x 44 (L x W x H, mm),1RU 

 

RG-S6220 switch is a class A product. In a domestic environment, this product may cause radio interference in 

which case the user may be required to take adequate measures. 

 

The 10G or 40G Ethernet port of the RG-S6220-48XS4QXS V1.XX switch supports direct attach copper (DAC) 

cable. The SFP+ port supports 1-meter, 3-meter and 5-meter cable, and the QSFP+ port supports 3-meter cable. 

For a detailed model and specification, refer to Appendix B. 

Product Appearance 

The hardware of the RG-S6220-48XS4QXS V1.XX includes the chassis, the power supply system and the heat 

dissipation system. 

 

The power supply system: Provides two power supply slots, which support 1+1 power supply redundancy. It is 

recommended users configure power supply redundancy. 

 

The heat dissipation system: Provides four power supply slots, which support 3+1 fan redundancy. It is 

recommended users configure all fans redundancy. 

Figure 1-1    Appearance of the RG-S6220-48XS4QXS V1.XX 

Содержание RG-S6220-24XS

Страница 1: ...RG S6220 Series Switches Hardware Installation and Reference Guide V1 06...

Страница 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption Statement This document is provided as is The contents of this document are subject to change without any n...

Страница 3: ...taining Technical Assistance Ruijie Networks Website http www ruijienetworks com Service Email service_rj ruijienetworks com Technical Support http www ruijienetworks com service aspx Technical Suppor...

Страница 4: ...A N A 2 1 1 1 RG S6220 48XT4QXS N A 48 4 N A N A 3 1 1 1 RG S6220 24XS 24 N A N A N A 2 3 1 1 1 An SFP port supports both 10Gbase R and 1000base X A QSFP port support both 40G mode and 40 x 10G mode 1...

Страница 5: ...dules and two power modules Dimensions 440 x 420 x 44 L x W x H mm 1RU RG S6220 switch is a class A product In a domestic environment this product may cause radio interference in which case the user m...

Страница 6: ...000Base T RCMI Ethernet port Console 10G SFP port 40G QSFP port The RG S6220 48XS4QXS V1 XX supports 10G SFP module and 1G SFP module But the 10G SFP module cannot function as the 1G SFP module Port 1...

Страница 7: ...s connected with the serial port of terminal PC to perform system debugging configuration maintenance management and host software uploading 10 100 1000M RCMI management port This is an out band Ether...

Страница 8: ...rmally RCMI port indicator RCMI Off The port is not linked up Green The port is linked up in 1000M mode Yellow The port is linked up in 10M or 1000M mode Blinking Data are transceiving at the port Cyc...

Страница 9: ...eat Dissipation The working temperature of the RG S6220 48XS4QXS V1 XX switches is 0 50 and the heat dissipation design needs to ensure the stability safety and maintainability in such environment The...

Страница 10: ...0Gbase T Port Unsupported Temperature Warning Support temperature warning and over temperature protection EMC GB9254 2008 CLASSA EMI GB4943 2011 Working Temperature 0 C to 50 C Storage Temperature 40...

Страница 11: ...220 48XS4QXS V2 XX Front Panel Figure 1 7 Front Panel of the RG S6220 48XS4QXS V2 XX Notes Switch status indicator PWR1 status indicator PWR2 status indicator MGMT management interface indicator Fan s...

Страница 12: ...oid device damage use qualified USB flash disks of good brands At the same time the local USB interface is compatible with most of the USB controllers except some USB flash disks Console port Use RS 2...

Страница 13: ...t is not linked up Green The port is linked up in 1000M mode Yellow The port is linked up in 10M or 1000M mode Blinking Data are transceiving at the port Cycling blinking green yellow and red This sta...

Страница 14: ...ice can work normally in specified environment Dust the device every three months to avoid blocking the ventilation openings The RG S6220 48XS4QXS V2 XX supports fan module M6220 FAN II F and provides...

Страница 15: ...humidity 10 to 90 RH non condensing Weight Net weight 11 kg including four fan modules and two power modules Dimensions 440 x 500 x 44 L x W x H mm 1 RU RG S6220 48XT4QXS switch is a class A product I...

Страница 16: ...lex mode of 10Gbase T 1000Base T and 100Base TX Back Panel Figure 1 13 Back Panel of the RG S6220 48XT4QXS Notes Power supply module slot USB2 0 interface Fan module slot Asset management label Ground...

Страница 17: ...45 connector This interface is connected with Ethernet port of a PC to perform program downloading This interface also supports DCMI protocol and users can do remote management and maintenance for the...

Страница 18: ...fan modules are in the position and working normally Solid yellow Only three fan modules are in the position Solid red 1 A fan fails 2 The number of the fan module is less than three 10GBase Tport sta...

Страница 19: ...M6220 FAN F and provides fan speed regulation fan failure warning and fan hot plugging Figure 1 6 Ventilation and heat dissipation of the RG S6220 48XT4QXS Leave sufficient space in the front and at...

Страница 20: ...g temperature 0 C to 50 C Storage temperature 40 C to 70 C Working humidity 10 to 90 RH non condensing Weight Net weight 9 5 kg including four fan modules and two power modules Dimensions 440 x 480 x...

Страница 21: ...xtension module Slot 2 The RG S6220 24XS supports10G SFP module and 1G SFP module But the 10G SFP module cannot function as the 1G SFP module The RG S6220 24XS supports two extension module slots Baff...

Страница 22: ...RJ45 connector This interface is connected with the serial port of terminal PC to perform system debugging configuration maintenance management and host software uploading 10 100 1000M RCMI management...

Страница 23: ...his status helps to locate the device position Fan module indicator Fan Solid green All fan modules are in the position and working normally Solid yellow Only three fan modules are in the position Sol...

Страница 24: ...at the back of the chassis at least 20 cm for ventilation It requires at least three fan modules to work normally Baffles need to be installed in the empty fan module slots to ensure ventilation and...

Страница 25: ...rks normally SFP port indicator 1F 12F Off The port is not linked up Solid green The port is linked up Blinking Data are transceiving at the port Specifications Model M6220 12XS Applicable Model RG S6...

Страница 26: ...e DAC and QSFP module hot plugging Indicator Specifications Indicator Panel Identification Status Meaning Status Indicator Status Off The module is not powered up Solid red The module fails or the mod...

Страница 27: ...ty 10 to 90 RH non condensing Weight Net weight 0 5 kg Dimensions 224 5 x 110 x 36 8 L x W x H mm The QSFP port of the M6220 02QXS supports 40G mode and 4x10Gmode Please configure the required working...

Страница 28: ...ly FC port indicator 1F 8F Ethernet mode Off The port is not linked up Solid green Port 10G 1G is linked up Blinking green Port 10G 1G is transceiving data 1F 8F FC mode Off The port is not linked up...

Страница 29: ...rance of the M6220 08XT Notes Extension module status indicator 1 8 are port status indicators 10GBASE T RJ45 port External Interface The M6220 08XT provides eight RJ45 ports which support 10GBASE T a...

Страница 30: ...orage temperature 40 C to 70 C Working humidity 10 to 90 RH non condensing Weight Net weight 0 75 kg Dimensions 224 5 x 110 x 36 8 L x W x H mm The M6220 08XT port supports only the full duplex mode o...

Страница 31: ...x H mm 1 5 6 M6220 FAN II F The M6220 FAN II F is the fan module of S6220 48XS4QXS V2 XX The M6220 FAN II F provides heat dissipation system and ensures system satiability The M6220 FAN II F supports...

Страница 32: ...ltage direct current HVDC input External Interface The front panel of the power supply module provides a three core power port which can be connected to standard 10 A power cord Indicator Indicator Pa...

Страница 33: ...the back When the device is being removed do not hold the power supply handle or the fan handle for these parts are not designed for bearing the entire weight of the device It will cause damage to th...

Страница 34: ...sure the antistatic wrist strap is well grounded Do not use bare hand to directly touch the components and the printed circuit board PCB when the boards are used Use an anti static shielding bag to p...

Страница 35: ...electricity And sometimes the materials may suffer from mechanical performance change and metallic parts may get rusted On the other hand in an environment with low relative humidity the insulating st...

Страница 36: ...as needed Safety Grounding The device using AC power supply must be grounded by using the yellow green safety grounding cable Otherwise when the insulating resistance decreases between the power suppl...

Страница 37: ...is difficult to shield Effective measures should be taken for the power system to prevent electric grid interference The working ground of the routers should be properly separated and kept as far as...

Страница 38: ...n guide Packing list Pouched documents Module Carton Various modules Packing list Quick installation guide A normal delivery should contain the above mentioned items which may differ from the actual d...

Страница 39: ...g before installation Verify the following requirements before installation The installation location provides sufficient space for heat dissipation The installation location meets the temperature and...

Страница 40: ...of the same model should be ready and tightened Various boards of the equipment should be installed securely and the fastening screws on the panel should be tightened All wiring inlets at the top and...

Страница 41: ...ckets 1 Take out the two L shape brackets and eight M4 8FMO countersink screws from the plastic package 2 Install the brackets at the side panels of the switch and fix the brackets with four M4 FMO co...

Страница 42: ...depth of 800mm 1200mm Mounting the Switch to a Workbench In some cases users do not have the 19 inch standard cabinet The common solution is to place the switch on a clean workbench The operation is s...

Страница 43: ...o avoid wrong insertion If the position is not proper withdraw the inserted module and re insert it If the screws cannot be tightened it is probably because the fan module is not fully inserted Please...

Страница 44: ...fix the extension module in the switch chassis Figure 3 6 Installing an M6220 series extension module Insert the extension module smoothly Pay attention to the direction of the extension panel to avo...

Страница 45: ...er Module 1 Take a new power module out of the package and confirm the input mode and the input parameters of the power module match the requirements 2 Remove the power baffle and take the plane print...

Страница 46: ...k of RG S6220 First connect the PGND to the grounding terminal of the cabinet and then connect the grounding terminal to the grounding bar of the equipment room Precautions The cross sectional area of...

Страница 47: ...the NMS or a control terminal 2 Insert the single mode or multi mode fiber into the appropriate interface according to the identification on the panel of the line card Distinguish the Rx Tx end of th...

Страница 48: ...binet Verify that there is sufficient space around the device especially in the front and at the back of the device at least 20cm Verifying the Cables Verify that the fibers and twisted pairs match th...

Страница 49: ...ort of the PC 2 Connect one end of the console cable RJ45 to the console port of the switch Setting Terminal Parameters Step One Start the PC and run the terminal simulation program on the PC such as...

Страница 50: ...column of Connect Using field select the serial port you want to use Figure 4 3 After the serial port is selected click OK The Serial Port Parameter Setting window is displayed as shown in Figure 4 4...

Страница 51: ...the power supply voltage complies with the requirement of the switch Check if the console cable is correctly connected the terminal can be a PC used for configuration is already started and the param...

Страница 52: ...th the management software When the indicator of the host or the extension module is red or flashing it indicates a failure in which case you need to find out the cause and turn off the power when nec...

Страница 53: ...e it with a qualified one and then connect the power cables Replacing Lithium Battery The built in lithium batteries can support the real time clock of the RG S6220 series switches without external po...

Страница 54: ...e power connection Check the installation of the power supply module Check the plug in units of each module Check the installation and fastening of the modules Check the indicators on the device and t...

Страница 55: ...Description After the system starts the fans in the fan module do not work or the Status indicator is OFF Troubleshooting Check if the connection between the fan module and the backplane is secure and...

Страница 56: ...the fiber interface is inserted into the optical module and the optical fiber is properly connected the link cannot be set up Troubleshooting 1 Check whether the receiving and sending ends are wrongly...

Страница 57: ...on and influenced by external crosstalk It is recommended to use CAT6A shielded wire or wires with higher specifications for the cabling of the new equipment room CAT6A or CAT7 shielded wire can maxim...

Страница 58: ...put Transmit Data 3 Output Transmit Data Input Receive Data 6 Output Transmit Data Input Receive Data 4 5 7 8 Not Used Not Used Figure A 3 shows the feasible connections of the straight through and cr...

Страница 59: ...of Received Light dBm min max min max MINI GBIC SX MM850 850 MF No 9 5 3 17 0 MINI GBIC LX SM1310 1310 SF No 9 5 3 20 3 GE eSFP SX MM850 850 MF Yes 9 5 3 17 0 GE eSFP LX SM1310 1310 SF Yes 9 5 3 20 3...

Страница 60: ...ter AWG Data Rate Gb s DDM Supporte d Yes No XG SFP CU1M Passive SFP 1 28 10 3125 No XG SFP CU3M Passive SFP 3 28 10 3125 No XG SFP CU5M Passive SFP 5 26 10 3125 No Models and Technical Specifications...

Страница 61: ...m Fiber Type Core Size m Modular Bandwidth MHz km Max Cabling distance Intensity of Transmitte d Light dbm Intensity of Received Light dbm DDM Supported Yes No min max min max FC2G SFP SR MM850 850 MF...

Страница 62: ...ons for installation Make sure that the PE terminal of the power arrester has been well grounded After the switch AC power plug is connected to the socket of the power arrester lightning protection ca...

Страница 63: ...nding terminal of the switch 3 Use the multimeter to check whether the grounding line for the arrester is in good contact with the switch grounding terminal and the framework 4 According to the descri...

Страница 64: ...switch Ethernet port to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact with the switch grounding terminal Use...

Страница 65: ...e diameters After cabling is fixed the bend radius of a common coaxial cable should be over seven times greater than its diameter The bend radius of this type of cables that often bend or suffer remov...

Страница 66: ...versed by cables should have a smooth and fully rounding surface or an insulated lining Proper buckles should be selected to bundle up cables It is forbidden to connect two or more buckles to bundle u...

Страница 67: ...f moving parts The power cables connecting moving parts such as door grounding wires should be reserved with some access after assembled to avoid suffering tension or stress When the moving part reach...

Страница 68: ...n should be bundled up into cable bunches with cables in cable bunches clean and straight Binding by using buckles should be performed according to Table D 1 Cable Bunch Diameter mm Binding space mm 1...

Страница 69: ...ll as away from dust If the dust is unavoidable keep the door and window away from the pollution source The machine room should be away from the residential area Otherwise the machine room should meet...

Отзывы: