background image

RDLC320 Controller User Manual

3

/

45

© 2016 Ruida Technology. All Rights Reserved.

9.1 Manufacturer Parameters....................................................................................34
9.2 User Parameters.................................................................................................. 37

Chapter 10 Controller to PC with Single NIC.........................................................41

10.1 Single Controller Connects to PC with Single NIC..........................................41
10.2 Single Controller Connects to PC with Multi-NIC...........................................42
10.3 Multi-controller Connects to PC via Concentrator........................................... 43
10.4 Multi-controller Connects to PC via Concentrator, Concentrator connects to
Router........................................................................................................................44

Содержание RDLC320

Страница 1: ...r Manual Shenzhen RuiDa Technology CO LTD Tel 86 0755 26066687 Fax 86 0755 26982287 Web www rd acs com E Mail support rd acs com Add 1B 1 Building 5 Tian an Nanyou Industry Area Dengliang Road Nanshan District Shenzhen P R C ...

Страница 2: ...rt CN2 10 4 4 3 axle Spacing and Special Input Interface CN3 CN4 11 4 5 X Y Z axle Motion Drive Interface 12 4 6 Laser Power Control Interface CN6 CN7 13 4 7 Water Protect Input Interface CN5 14 Chapter 5 Examples of Laser Power Interface 15 5 1 Digital Laser Power Supply of Glass Tube 15 5 2 Analog Laser Power Supply of Glass Tube 15 5 3 RF CO2 Laser 16 Chapter 6 Examples of Driver Interface for ...

Страница 3: ...Parameters 37 Chapter 10 Controller to PC with Single NIC 41 10 1 Single Controller Connects to PC with Single NIC 41 10 2 Single Controller Connects to PC with Multi NIC 42 10 3 Multi controller Connects to PC via Concentrator 43 10 4 Multi controller Connects to PC via Concentrator Concentrator connects to Router 44 ...

Страница 4: ... and modify the products and functions of this product stated herein as well as amend any documents attached to this product without prior notification 3 The users should peruse this manual prior to using the product stated herein Ruida Technology shall not be responsible for the direct indirect special incidental or corresponding losses or damages arising out of improper use hereof or of this pro...

Страница 5: ...tability high voltage or static electricity rejection and friendly man machine operation this system is provided with stronger software function including perfect 3 axle motion control function large capacity file storage two channel adjustable digits analog laser power control interface USB driver of stronger compatibility multi channel general special IO control and real time clock and battery i...

Страница 6: ... IO Feature Input Port Nil Two ways 4 ways two for general two for specialties Output Port Nil 1 way low current so additional drive is needed 4 ways 500mA high current for each OC output two for general two for specialties Software Feature Power off restart for Engraving NO YES YES Online Modification Laser Power Speed NO YES YES Multi origin Logics NO NO YES Parameter Backup Logics NO NO YES Wor...

Страница 7: ... 45 2016 Ruida Technology All Rights Reserved Chapter 2 Installation Dimension 2 1 Installation dimension of IO Interface Board The unit of all sizes is millimeter mm and the size accurate to 0 1mm Figure 2 1 1 4 M3 Stud rivet 4 high ...

Страница 8: ...oller User Manual 8 45 2016 Ruida Technology All Rights Reserved 2 2 Panel Dimension The unit of all sizes is millimeter mm and the size accurate to 0 1mm Figure 2 2 1 4 M3 Stud rivet 10 high 4 M3 Stud rivet 8 high ...

Страница 9: ...l Rights Reserved Chapter 3 Pictures and Interfaces 3 1 Picture of Main Board For more detailed of pin description see the Chapter 4 Description of Interface Signal for IO board 3 2 Picture of Panel Figure 3 1 1 IO Picture of Board Figure 3 2 1 Picture of Panel ...

Страница 10: ...3 General output 3 with the function reserved 4 Out2 General output 2 and the signal port of operating status If this port is externally connected with the relay the relay coil is broken over when it works no influence is produced when it suspends working When its work ends or is stopped manually the relay coil will be cut off 5 Wind General output 1 When the blower control is enabled this port wi...

Страница 11: ...cted the work suspended and the laser closed 3 FootSW Input port of foot switch The connection method is when the pedal is stepped down the low level signal will be inputted to this port when the pedal is released the port will be disconnected or the high level signal can be inputted to this port when the stepped down pedal is held for not less than 100 ms if the machine lies idle it can be starte...

Страница 12: ...set so as to lead to the collision of axles 4 5 X Y Z axle Motion Drive Interface The interfaces of the above three motion axles are the same 6Pin 3 81mm space The Axle X interface is exampled Pin Symbols Definitions 1 GND Kernel power ground output only used for common cathode connection of driver 2 xDir Differential plus end of directional signal 3 xDir Differential minus end of directional sign...

Страница 13: ...F laser this pin will not be used 2 When the laser is a glass tube if the used laser is outputted in the high level form this pin will be connected with the laser power enable end and used to control the ON Off of laser 4 LPWM1 Power control interface of laser laser tube 1 When the laser is the RF laser this pin will not be used 2 When the laser is a glass tube and the laser power PWM end is high ...

Страница 14: ... system will warn If the water protector 1 is not enabled the controller will not detect the input port of water protector 1 and the user not connect the water protector 1 3 WP2 The input port of water protector for the second laser power source When the water protector 2 is enabled the controller will detect the input port of water protector 2 If this port is of low level it will be deemed normal...

Страница 15: ...20 Controller User Manual 15 45 2016 Ruida Technology All Rights Reserved Chapter 5 Examples of Laser Power Interface 5 1 Digital Laser Power Supply of Glass Tube 5 2 Analog Laser Power Supply of Glass Tube ...

Страница 16: ...RDLC320 Controller User Manual 16 45 2016 Ruida Technology All Rights Reserved 5 3 RF CO2 Laser ...

Страница 17: ...signals of motor driver for RD controller are the 5V signals that should directly be abutted with the corresponding terminals to the driver The interface pulse end of each motor driver for RD controller can provide such two signals as the rising edge walk and falling edge travel The improper use of the pulse end signal may give rise to the lost steps even back run and finally dislocation of proces...

Страница 18: ... 3MD560 Figure 6 2 1 and 6 2 2 show the wiring scheme of RD controller and Leadshine driver 6 3 Valid Falling Edge for Pulse Signal The driver pulse ends of drivers for step servo motors presently produced by most of manufacturers are valid falling edge The typical companies include BERGER LAHR Beijing HollySyn Motor Technology Co Ltd Shenzhen YAKO Automation Technology Co Ltd Shenzhen Baishan Mec...

Страница 19: ...nzhen Baishan Mechatronics Co Ltd 2 The drivers with common anode input signals such as YKA2304ME from Shenzhen YAKO Automation Technology Co Ltd Q2HB34MB and Q2HB44MA B from Shenzhen Baishan Mechatronics Co Ltd Figure 6 3 3 Three Inputs Valid Falling Edge and Common Anode Connection Figure 6 3 1 Four Inputs Valid Falling Edge and Common Anode Connection Figure 6 3 2 Four Inputs Valid Falling Edge...

Страница 20: ...ller User Manual 20 45 2016 Ruida Technology All Rights Reserved Chapter 7 Examples of IO port Wiring 7 1 Input Port The input connection at X Y minus spacing is exampled Figure 7 1 1 Example of Input port Connection ...

Страница 21: ...RDLC320 Controller User Manual 21 45 2016 Ruida Technology All Rights Reserved 7 2 Output Port Figure 7 2 1 Example of Output port Connection ...

Страница 22: ...duction to the Main Interface 1 Idle Interface display system time day month year 2 Pause Interface 3 Running Interface display run time of the selected file hour minute second File XX File Number XXXX Max Power XX X Run Speed XXX mm s System Idle 25 12 2010 Figure 8 1 1 Figure 8 1 2 Figure 8 1 3 File XX File Number XXXX Max Power XX X Run Speed XXX mm s System Paused 00 12 40 File XX File Number ...

Страница 23: ...the keyboard Maximum energy is expressed by percentage and accurate to 0 1 The unit of processing speed is millimeter a second mm s When there is a laser tube the interface only shows the maximum energy of this tube as shown in the above figure If there are two laser tubes that are enabled the interface show the maximum energy of two laser tubes The main idle interface is taken for example as show...

Страница 24: ... continuous engraving if the Enter key is pressed in this interface the de energizing for continuous engraving can be started in order to process such a figure continuously After the de energizing for continuous engraving is started the interface will show Looking for cutoff point please wait The waiting time has something to do with the data size of last processing The larger the data size is the...

Страница 25: ...Max Power key On four main interfaces i e idle system running system and suspended system work finished interface this key can be pressed On pressing this key if the manufacturer only provides a single laser tube or if there is a double path laser tube but the user only enables one path it only shows the maximum energy of this path laser tube and the interface shows the same as Figure 8 2 2 If two...

Страница 26: ...he parameter of the layer that is being processed now The power and the speed parameters corrected when the work is not started will influence the following operations bordering bursting and manually shifting the axle on the keyboard If the three parameters will be modified after the work is started it will only influence the layer that is being processed but neither the keyboard parameters set in...

Страница 27: ...ours accurate to the millisecond Delete All Memory Files to delete the data of all memory files on the controller Format Memory to format the memory on the controller There are Quick Format and Complete Format for option If there is some abnormity in memory you may check the invalid block with the format function Clear All File Number to delete the corresponding processing times to each memory fil...

Страница 28: ...g succeeds the system will return to the prior interface after the bell rings On selecting the Deletion and pressing the Enter key this file in the memory will be deleted Selecting the Work Time Preview and pressing the Enter key to start the work time preview feature of the certain file If Track Frame is selected the frame of the graph is previewed Then if Clear File Number is selected the work n...

Страница 29: ... the controller will take the current X Y axle position of the machine as the relative origin of the figure if the multiple setpoint logic is selected by the system it is invalid to press this key at any time 9 Frame key It is valid to press this key under the idle system interface and the work finished interface Press this key and the bordering will be operated on the currently selected file 10 E...

Страница 30: ...m minimum coordinates The maximum speed of key movement is the speed value set on the keyboard when the system lies idle After the polarity of directional signal for each axle of the machine is adjusted well if you press the Left key and the X axle will move rightward and if you press the Up key and the Y axle will move down which mean the key polarity of the axles moving to the opposite direction...

Страница 31: ...es as follows Press the Up and Down keys to select the desired entry Press the Enter key and the corresponding axles will reset Only when the reset of this axle is activated in the manufacturer s parameters can the resetting will function Press the Esc key to return to the prior menu 3 When the cursor stops at Inch Setting or Laser setting the inching distance or the Laser shot time can be set 4 W...

Страница 32: ...e after the multiple origin logic is enabled the four origins can independently be prohibited and enabled Once the multiple origin logic is selected and if the serial number of the next origin is 1 and four origins are enabled when the memory file function is started or the processing file is uploaded into the PC and this file selects Take the Original Origin as current Origin the work started for...

Страница 33: ...ogy All Rights Reserved the focus When there is z axes and the z axes reset function is enabled the auto focusing is valid press the Esc key to return the prior menu 8 The item Langue helps you to select a appropriate langue which is displayed on the panel ...

Страница 34: ... a case the polarity of keys should be modified Control Mode Double PWM and direction single pulse are optional it is configured with the motor driver types In general direction single pulse is selected Hard limit spacing Protection it is used for whether the hard spacing protection of this axis is enabled Reset Enable if the machine is configured this axis Reset Enable should be opened if no Rese...

Страница 35: ...eans the farthest distance that the motion axis can move which is determined in accordance with the actual condition of the machine Key Jump off Speed it means the starting speed to move the axis by way of the keys on the keyboard which can t be higher than the jump off speed Key Acceleration it means the acceleration to move this axis by way of the keys on the keyboard which can t be higher than ...

Страница 36: ... mode and bi direction mode for optional If it is single direction feeding it is unnecessary to check the coordinates feeding can be conducted in the single direction mode if it is bi direction feeding the system will check the maximum and minimum coordinates The odd sequence means feeding should be done to one direction and the even sequence means feeding done to the other direction The initial d...

Страница 37: ...r Parameters 1 Cutting Parameters Only affect cutting arts Idle Speed this parameter decides the highest speed of all non lighting straight lines for the machine in the movement process Idle Acceleration it means the highest acceleration of all non lighting straight lines Idle stroke speed and idle stroke acceleration can be set higher to reduce the working time of the whole graphics but if they a...

Страница 38: ... set as a lower value Scan Mode it is divided into general mode and special mode If in special mode the laser power should be increased The smaller the spot percentage is the more the laser power reduces The laser power should be set larger to reach the same scanning depth The purpose to select the special mode is to emit laser light at high power in short time to get the flatter bottom on depth s...

Страница 39: ... certain length outside the actual frame of the figure on the preview cutting of frame If the frame crosses the border the interface will prompt it If the Enter key is pressed at this time the system will cut the border at the maximum minimum coordinates and then framing operation This operation can be given up 5 Other User Parameters Array Mode Two way array or one way array can be selected only ...

Страница 40: ...ng it means the distance from the lens focal point of laser head to Z axis original point If there is no automatic focusing function this parameter is invalid Backlash X The backlash of X axis set the value according to the actual machine accurate to 1 um if this value is not 0 the control system will make compensation for backlash Backlash Y The backlash of Y axis set the value according to the a...

Страница 41: ... 10 1 Single Controller Connects to PC with Single NIC Step 1 Set the work mode to be ETHERNET on the panel And then set the controller IP address between 192 168 001 100 192 168 001 149 Step 2 Set the IP address in the PC The IP address is between 192 168 001 2 192 168 001 049 See picture1 1 Picture1 1 PC IP configuration ...

Страница 42: ...1 Step2 The second NIC should connect to internet with router So the router should be configured 1 Open IE and input the IP address 192 168 1 1 just for most NIC And then enter the NIC configuration interface Then input the password default is Admin Set the router IP address to be 192 168 2 1 make sure the IP to difference with other routers 2 Get the router DNS Record the DNS server ...

Страница 43: ...lti controller Connects to PC via Concentrator 1 PC connects the input of the concentrator Multi controller connects to the output of the concentrator 2 Different IP address should be configured for each controller But all of the IP address should be set between 192 168 001 100 192 168 001 149 3 Set the PC IP address between 192 168 001 2 192 168 001 049 ...

Страница 44: ... and the Concentrator connects to Router 1 PC and multi controller connect to output on the concentrator 2 Different IP address should be configured for each controller But all of the IP address should be set between 192 168 001 100 192 168 001 149 3 Configured step please reference to Single Controller Connects to PC with Multi NIC ...

Страница 45: ...nology Co Ltd Without our permission any company or individual shall not reprint copy or distribute the content related to this product manual We keep the rights to revise or update the contents without notice If any comments and suggestions please feel free to contact us Phone 0755 26066687 Fax 0755 26982287 Website www rd acs com Address 1B 1 Building 5 Tian an Nanyou Industry Area Dengliang Roa...

Отзывы: