NOTE:
Always use clean automatic transmission fluid (ATF) in the power unit. Do not
mix types. Check oil level monthly and add as needed (see Fill & Prime instructions) to
prevent unit from pumping air. Change fluid annually to remove condensation and
entrapped debris.
Check the following monthly to ensure proper operation:
1.
Wiring, electrical connectors, power cables (positive and ground), valves, and
coils for any corrosion, rust or loose bolts. Electrical components must be kept
free of corrosion and rust in order to function properly.
2.
Hoses/fittings for any cracks, leaks or any other exterior damage. Tighten all
fittings as needed.
3.
Plastic reservoir for leaks or other damage.
4.
Vent cap for any dirt or debris.
SINGLE ACTING:
Raise the hoist by pressing and holding the “UP” pushbutton on the control station. This
activates the power unit and directs oil to the base end of the hoist cylinder. Releasing the
pushbutton will stop raising the hoist and will hold its position.
NOTE:
The power unit is equipped with a factory-set hydraulic relief valve that will
bypass at 3200 PSI when the hoist reaches a fully raised position or whenever the load
being lifted exceeds the hoist capacity. Care should be taken not to let the pump bypass
for long periods of time, as this will put stress on the whole hydraulic and electrical
system. To stop the pump from bypassing, release the “UP” button on the control station.
Lower the hoist by pressing and holding the “DOWN” pushbutton on the control station.
This activates the solenoid valve and directs oil from the cylinder back to the power
unit’s reservoir. Releasing the pushbutton will stop lowering the hoist and it will hold its
position.
DOUBLE ACTING:
Raise the hoist by pressing and holding the “UP” pushbutton on the control station. This
activates the power unit and directs oil to the base end of the hoist cylinder. Releasing the
pushbutton will stop raising the hoist and it will hold its position.
NOTE:
The power unit is equipped with a factory-set hydraulic relief valve that will
bypass at 3200 PSI when the hoist reaches a fully raised position or whenever the load
being lifted exceeds the hoist capacity. Care should be taken not to let the pump bypass
for long periods of time, as this will put stress on the whole hydraulic and electrical
system. To stop the pump from bypassing, release the “UP” button on the control station.
Содержание MONARCH
Страница 2: ...Stock 1657447 036226 2 Contents Warnings 3 4 Descriptions 5 7 Installation 8 18 Operation 19 21 ...
Страница 9: ...Stock 1657447 036226 9 ...
Страница 10: ...Stock 1657447 036226 10 ...
Страница 11: ...Stock 1657447 036226 11 ...
Страница 12: ...Stock 1657447 036226 12 ...
Страница 13: ...Stock 1657447 036226 13 ...
Страница 14: ...Stock 1657447 036226 14 ...
Страница 16: ...Stock 1657447 036226 16 FIGURES 2a 3a SINGLE ACTING SCHEMATICS If 2 wire coil ground wire ...
Страница 17: ...Stock 1657447 036226 17 FIGURE 2b 3b DOUBLE ACTING SCHEMATICS If 2 wire coil ground wire ...