Rebooting and Resetting the AP and CM
T504 Strand Mount Concurrent AP with Integrated CM Installation Guide, 800-70610-001 Rev A
44
Figure 17. Location of the reset button
4
Using a pen or a similar pointed object, momentarily press the reset button on
the reset adapter assembly to reboot the AP and CM, or hold the reset button
for 10 seconds to reset the AP and CM to factory defaults.
5
Replace the Reset button and diagnostic Ethernet port cap.
You have completed resetting the AP and CM to their factory default settings and/
or rebooting the AP and CM.
Remotely Rebooting the AP
NOTE
Before starting this procedure, you must first obtain the related MIBs from
Ruckus Wireless. Contact your authorized Ruckus Wireless sales representative or
Ruckus Wireless Support. Visit
http://support.ruckuswireless.com/
contacts
for Ruckus Wireless Support contact information (login required).
1
Connect the administrative computer to the same network as the T504.
2
Start your MIB browser.
3
Load the Ruckus Wireless MIBs onto the MIB browser.
4
In the MIB browser, specify the IP address of the T504 AP. (You can obtain this
information from the DHCP server on the network.)
5
Find the OID
1.3.6.1.4.1.25053.3.1.4.7.3
(ruckusZFT504ControlLED).
6
Set the value to
14
(powerCycleAP).
You have completed remotely rebooting the access point using SNMP.