Installing the T504
Connectors and Ground Point
T504 Strand Mount Concurrent AP with Integrated CM Installation Guide, 800-70610-001 Rev A
18
Connectors and Ground Point
identifies the connector and external ground point on the T504.
describes this connector and the ground point.
Figure 4. T504 connectors and ground point
Table 2.
Connectors and ground point on the T504
No.
Label
Description
1
Coaxial Cable
Connector
Connects to the CMTS at the headend using a tap on the plant,
and provides AC POC to the T504. For more information, refer to
.
2
Optional
External Earth
Ground Point
The T504 is normally earth-grounded by the cable strand.
However, if the cable strand is not earth grounded, then connect
an external earth ground to the T504 using this screw-and-washer
set.
1
2