Rubicon Synapse H2O Скачать руководство пользователя страница 7

H2O Manual | 7

3.8 Cleaning and maintenance 

Cleaning and maintenance should only be 

carried out with the Synapse H2O disconnected 

from the grid and PV supplies. Before taking 

any action, make sure that the system has 

been correctly disconnected by deactivating the 

circuit breakers and or isolators that power it. To 

clean the H2O, wipe the exterior surface with 

a damp (not wet) soft, non-abrasive cloth. Pay 

attention to the cooling slots and any dust build-

up thereon which may affect the ability of the 

H2O to dissipate heat generated.

Do not try to repair the device yourself in case 

of any malfunction. If this occurs, contact 

Rubicon’s customer service. The system does 

not require any special maintenance, except 

for standard physical cleaning to ensure good 

airflow  and  the  maintenance  required  by  any 

electrical device connected with screws and 

terminals that need to be tightened.

3.9 General hazards resulting from  

non-compliance with safety standards

The technology employed in the manufacturing 

of the Synapse H2O ensures safe handling 

and operation. Nonetheless, the system might 

pose  hazards  if  it  is  used  by  unqualified  staff 

or handled in a way that is not specified in this 

user manual.

Any person in charge of the installation, 

commissioning, maintenance, or replacement 

of  a  Synapse  H2O  must  first  read  and 

understand this user manual, especially the 

safety recommendations and shall be trained to 

do so.

3.10 general safety requirements

Operator

The person in charge of handling the electrical 

device is responsible for the safety of persons 

and property.

Avoid accidental re-connection of the system 

using signs, isolating locks and closing or 

blocking the work site. Accidental reconnection 

may cause serious injuries or death.

Determine conclusively, using a voltmeter, 

that there is no voltage in the system before 

commencing work. Check all the terminals to 

make sure that there is no voltage in the system, 

on both AC and DC power interfaces.

Insulate all the system’s power conducting 

components which could cause injuries while 

carrying out the works. Confirm that dangerous 

areas are clearly marked and access is 

restricted.

3.11 Local requirements

In all cases, local regulations shall be followed 

and take preference over this manual or other 

documents related to the Synapse H2O. No part 

of this manual shall supersede any local laws, 

bylaws or other regulations. These include but 

are not limited to earthing, temperature settings, 

local electrical isolation requirements and so on.

3.12 Other considerations

This device is exclusively designed to manage 

a hot water geyser, to be powered by either the 

grid, a solar array or both and is to be installed 

in a domestic setting. 

The Synapse H2O should only be used for this 

purpose. Rubicon is not liable for any damages 

caused by inappropriate installation, use or 

maintenance of the system.

To ensure safe use, the Synapse H2O must 

only be used in compliance with the instructions 

in this manual. Legal and safety regulations 

must also be adhered to to ensure correct use.

Содержание Synapse H2O

Страница 1: ...Synapse H2O PV Geyser Controller Technical Manual www rubiconsa com...

Страница 2: ...0 General safety requirements 7 3 11 Local requirements 7 3 12 Other considerations 7 4 Device description 8 4 1 Overview and description 8 4 2 Identification 8 5 Installation 9 5 1 Safety 9 5 2 Insta...

Страница 3: ...Figure 1 below shows a typical installation 1 1 Contents of the box Inside the box you should find 1 x Synapse H2O controller 1 x mounting bracket 1 x securing screw 1 x temperature probe 1 x pair MC...

Страница 4: ...ximum Power Output 1500W MPPT Range 130 220VDC depends on element Connection MC4 Solar Connectors Installation Pre requisites External PV Isolator and SPD protection Voltage 60 220V Modulated DC varia...

Страница 5: ...d to IEC 60730 ICASA RF approval pending CE Self Certified for EMC Safety IEC 60950 1 Electrical Safety Designed to Class B IEC 60730 Maximum Ambient Temperature 0 C to 30 C full output limited output...

Страница 6: ...staff lies with the company that the staff work for It is also the responsibility of the company to assess the ability of the worker to carry out any kind of work and ensure their safety Staff must co...

Страница 7: ...10 general safety requirements Operator The person in charge of handling the electrical device is responsible for the safety of persons and property Avoid accidental re connection of the system using...

Страница 8: ...the LED indicators please see the Operation section of the manual For more detailed information on the LED indicators please see the Operation section of the manual Figure 2 H2O PV geyser controller R...

Страница 9: ...as free airflow and at least 300mm clearance all around Is not subjected to heat generated by another device eg above a cooker or directly adjacent to the geyser It may not be mounted inside a cupboar...

Страница 10: ...or the local isolator depending on local regulations Ensure that the Live Neutral and Earth conductors are all connected securely and according to the labels on the H2O and the Geyser Ensure that the...

Страница 11: ...ectors on the H2O See Fig 5 Ensure that the H2O is protected with Surge Protection Devices SPD s on both the AC and DC supply interfaces Temperature sensor The H2O is supplied with a temperature senso...

Страница 12: ...stem will remain below dangerous temperature levels To do this set the original mechanical thermostat marginally above the desired setpoints of the system but still within safe limits For example if t...

Страница 13: ...and the user app see section 7 AC setpoint 55 C Solar setpoint 55 C Boost setpoint 55 C Note it is recommended that an internet connection is used and commissioned as it enables full diagnostics and c...

Страница 14: ...py of which is available at www rubiconsa com H2O 7 Mobile applications and WiFi connectivity 7 1 APP introduction The Synapse H2O can be commissioned configured and monitored via the included Mobile...

Страница 15: ...ubiconsa com Once accredited an installer can enrol a site by opening the Installer s app with a mobile web browser from https rubicon installation web app login and logging in with the credentials yo...

Страница 16: ...eps have been completed tap the submit button Step 5 Finalise installation documentation This step gives the PDF summary document time to generate and download The installer must confirm the Installat...

Страница 17: ...main PCB for 3 seconds 7 4 User s App Synapse H2O is managed monitored and controlled with the H2O User s app The User s Application requires a Synapse H2O s user to have been enrolled by a Qualified...

Страница 18: ...s You can change the temperature setpoints for Grid Solar and Boost modes here Support Contact Rubicon for support from here Menu Energy consumption This view allows you to visualise your energy usage...

Страница 19: ...elow the Login button 7 4 1 Forgotten password If a user forgets or loses their password it can be reset Enter this link in a mobile device s browser https rubicon iot dev web app login In the screen...

Страница 20: ...sa com Port Elizabeth 4 Reith Street Sidwell Port Elizabeth Eastern Cape 6061 27 41 451 4359 salespe rubiconsa com East London Unit 1 Aloe Industrial Park Motor City Bonza Bay Road Beacon Bay East Lon...