3. Safety instructions

Please read and follow all the below safety 

instructions and precautions before installation 

and use of the Synapse H2O. 

3.1 Symbols

The following symbols are used in this manual to 

highlight and emphasise important information. 

The general meanings of the symbols used in 

the manual, and those present on the device, 

are as follows:

General

Caution

General 

Electrical 

Hazard

 Information

Prohibited 

Direct 

Current               

Reinforced

Insulation           

3.2 Purpose

These safety instructions are intended to 

highlight risks and dangers of improper 

installation, commissioning and use of the H2O 

device.

3.3 Transport damage check

Immediately after receiving the package, make 

sure that the packaging and the device have 

no signs of damage. If the packaging shows 

any sign of damage or impact, damage of 

the H2O should be suspected and it should 

not be installed. If this occurs, please contact 

Rubicon’s customer service.

3.4 Staff

 

This system should be installed, handled and 

replaced solely by qualified personnel.

Qualification  of  the  staff  mentioned  herein 

must meet all the safety-related standards, 

regulations and legislation applicable to the 

installation and operation of this system in the 

country concerned.

The  responsibility  to  select  qualified  staff  lies 

with the company that the staff work for. It is also 

the responsibility of the company to assess the 

ability of the worker to carry out any kind of work 

and ensure their safety. Staff must comply with 

workplace health and safety regulations. It is the 

responsibility of the company to provide their 

staff with the training necessary for handling 

electrical devices and to make sure that they 

familiarize themselves with the contents of this 

user manual.

3.5 Special hazards

The Synapse H2O is designed to form part of 

a domestic electrical installation. Applicable 

safety measures must be observed, and any 

additional safety requirements should be 

specified by the company who has installed or 

configured the system.

Dangerous voltages may be present in the 

system and any physical contact could cause 

a serious injury or death. Please ensure that 

all covers are securely fastened and that only 

qualified staff service the Synapse H2O. Ensure 

that the system is switched off or disconnected 

during handling

3.6 Installation location

The Synapse H2O may only be installed indoors, 

vertically  secured  onto  a  firm  surface  and  be 

protected from water, excessive dust, corrosion 

and humidity. It should never be installed 

directly below a geyser or in any location where 

a potential water leak could occur.  (See section 

5 for more info).

3.7 Alterations

It is strictly prohibited to carry out any alteration 

or modification to the Synapse H2O or any of its 

accessories.

Содержание Synapse H2O

Страница 1: ...Synapse H2O PV Geyser Controller Technical Manual www rubiconsa com...

Страница 2: ...0 General safety requirements 7 3 11 Local requirements 7 3 12 Other considerations 7 4 Device description 8 4 1 Overview and description 8 4 2 Identification 8 5 Installation 9 5 1 Safety 9 5 2 Insta...

Страница 3: ...Figure 1 below shows a typical installation 1 1 Contents of the box Inside the box you should find 1 x Synapse H2O controller 1 x mounting bracket 1 x securing screw 1 x temperature probe 1 x pair MC...

Страница 4: ...ximum Power Output 1500W MPPT Range 130 220VDC depends on element Connection MC4 Solar Connectors Installation Pre requisites External PV Isolator and SPD protection Voltage 60 220V Modulated DC varia...

Страница 5: ...d to IEC 60730 ICASA RF approval pending CE Self Certified for EMC Safety IEC 60950 1 Electrical Safety Designed to Class B IEC 60730 Maximum Ambient Temperature 0 C to 30 C full output limited output...

Страница 6: ...staff lies with the company that the staff work for It is also the responsibility of the company to assess the ability of the worker to carry out any kind of work and ensure their safety Staff must co...

Страница 7: ...10 general safety requirements Operator The person in charge of handling the electrical device is responsible for the safety of persons and property Avoid accidental re connection of the system using...

Страница 8: ...the LED indicators please see the Operation section of the manual For more detailed information on the LED indicators please see the Operation section of the manual Figure 2 H2O PV geyser controller R...

Страница 9: ...as free airflow and at least 300mm clearance all around Is not subjected to heat generated by another device eg above a cooker or directly adjacent to the geyser It may not be mounted inside a cupboar...

Страница 10: ...or the local isolator depending on local regulations Ensure that the Live Neutral and Earth conductors are all connected securely and according to the labels on the H2O and the Geyser Ensure that the...

Страница 11: ...ectors on the H2O See Fig 5 Ensure that the H2O is protected with Surge Protection Devices SPD s on both the AC and DC supply interfaces Temperature sensor The H2O is supplied with a temperature senso...

Страница 12: ...stem will remain below dangerous temperature levels To do this set the original mechanical thermostat marginally above the desired setpoints of the system but still within safe limits For example if t...

Страница 13: ...and the user app see section 7 AC setpoint 55 C Solar setpoint 55 C Boost setpoint 55 C Note it is recommended that an internet connection is used and commissioned as it enables full diagnostics and c...

Страница 14: ...py of which is available at www rubiconsa com H2O 7 Mobile applications and WiFi connectivity 7 1 APP introduction The Synapse H2O can be commissioned configured and monitored via the included Mobile...

Страница 15: ...ubiconsa com Once accredited an installer can enrol a site by opening the Installer s app with a mobile web browser from https rubicon installation web app login and logging in with the credentials yo...

Страница 16: ...eps have been completed tap the submit button Step 5 Finalise installation documentation This step gives the PDF summary document time to generate and download The installer must confirm the Installat...

Страница 17: ...main PCB for 3 seconds 7 4 User s App Synapse H2O is managed monitored and controlled with the H2O User s app The User s Application requires a Synapse H2O s user to have been enrolled by a Qualified...

Страница 18: ...s You can change the temperature setpoints for Grid Solar and Boost modes here Support Contact Rubicon for support from here Menu Energy consumption This view allows you to visualise your energy usage...

Страница 19: ...elow the Login button 7 4 1 Forgotten password If a user forgets or loses their password it can be reset Enter this link in a mobile device s browser https rubicon iot dev web app login In the screen...

Страница 20: ...sa com Port Elizabeth 4 Reith Street Sidwell Port Elizabeth Eastern Cape 6061 27 41 451 4359 salespe rubiconsa com East London Unit 1 Aloe Industrial Park Motor City Bonza Bay Road Beacon Bay East Lon...

Отзывы: