Date:
09-May-2019
Product name
RTX2018
File
: RTX2018 User Manual 1.0.docx
Ref.: FHA
Page: 30 of 34
This document and the information contained is property of RTX A/S, Denmark, and should be regarded as confidential.
Unauthorized copying is not allowed. The information in this document is believed to be correct at the time of writing. RTX A/S
reserves the right at any time to change said content, circuitry and specifications.
•
“Freq Offset” shows the frequency offset mea
sured in kHz of the signal. The offset is
estimated on the demodulated signal.
•
“RMS
EVM
”
shows the RMS (Root mean square) EVM (Error Vector Magnitude) of
the signal within the evaluation window.
•
“Peak
EVM
”
shows the Peak EVM (Error Vector Magnitude) of the signal within the
evaluation window.
The RTX2018 GUI also shows the results graphically.
below shows the graphs for a PI2-BPSK signal without b0 synchronisation. Thus, there is no
power template match again.