An error message will appear if the server cannot be found.
5.1.2
Frequency/Channel/Channel Frequency
The “Frequency” field is a drop
-down menu that allows the user to select various DECT bands:
•
DECT EU
•
DECT US
•
DECT Japan
•
DECT Korea
•
Manual
A set of channels can be selected for each band. The corresponding channel frequency is
shown in the “Channel Freq” box.
The channel frequency is selected simultaneously for both RX and TX.
5.1.3
Slot Types
Th
e “Slot Type” field
drop-down menu is used to select between predefined slot types.
The slot types are used to configure the TX measurements with respect to capture time and
evaluation window. The TX power ramp definition does also depend on this selection.
The following slots are available:
•
P32Z
•
PP32Z
•
P64Z
•
PP64Z
P32Z and PP32Z are standard DECT full slots with Z-field. PP32Z/PP654Z has a prolonged
preamble (a 16-bit extension of the preamble in the beginning).
If the user adjusts either the
“C
apture Timing
” or the “E
valuation Window
”
setting, the slot
type will change to
“U
ser Defined
”
.
5.1.4
Cable Loss
The
“C
able Loss
”
field is used to adjust the results within the GUI for cable loss (or transmission
loss). This value is used for both RX and TX. The range for the cable loss is -10 to +30 dB.
The cable loss correction is done within the GUI. The DLL does
NOT
contain a cable loss
feature.