KP Series
KP-4016/5032 Menu System 249
Bosch Security Systems, Inc.
Technical Manual
F.01U.304.914
Rev. 05
4.
Press the
SEL button
.
Disabled and Enabled appear in the panel display.
5.
Using the arrow buttons,
select
Enabled
.
6.
Press the
SEL button
.
7.
Press the
CLR
button to exit the menu.
To
configure the OKP device name
, do the following:
1.
Starting at the Service|OMNEO Setup menu, select
OKP
.
2.
Press the
SEL button
.
Device Name, DHCP, and IP Parameters appear in the panel display
.
3.
Using the arrow buttons,
select
Device Name
.
The name of the OKP card appears in the panel display with the first character of its name blinking
.
4.
Using the up and down arrow buttons or the Aux shaft encoder, select a
new character at the current position
.
5.
Using the left and right arrow buttons or the Main shaft encoder, move to the
next or previous character position
.
6.
Press
SHIFT
to insert a character at the current position.
7.
Press the
SEL button
.
OR
Press the
AUX
shaft encoder to move to the next character.
NOTE:
Press BACK or press the MAIN shaft encoder to cancel editing. A confirmation is required.
8.
Press
FWD
or move to the end of the name and Press the SEL button (or the AUX shaft encoder) to save changes.
9.
Repeat
steps
7
and
8
until you have modified the device name.
10.
Press
FWD
.
The message Save Name? appears on the panel display.
11.
Press the
SEL button
.
To
configure the OKP IP Address
, do the following:
1.
Starting at the Service|OMNEO Setup menu, select
OKP
.
2.
Press the
SEL button
.
Device Name, DHCP, and IP Parameters appear in the panel display
.
3.
Using the arrow buttons, select
DHCP
.
4.
Press the
SEL button
.
Disabled and Enabled appear in the panel display.
5.
Verify DHCP is
disabled
.
NOTE:
When making changes to the OKP IP parameters, DHCP must be disabled before changing the Domain
name or IP Address. If DHCP is enabled, you can still view the IP Parameters, but you cannot make changes
to them.
6.
Press
BACK
.
7.
Using the arrow buttons,
select
IP Parameters
.
NOTE:
SEL/FWD moves to the next octet, unless already on the last octet, in which case it save the current IP
Address. CLR/BACK moves to the previous octet, unless already on the first octet, in which case it cancels
editing of the IP Address.
8.
Press the
SEL button
.
IP Address, Gateway, Netmask, DNS Server, and Domain appear in the panel display.
9.
Press the
SEL button
.
The IP Address appears with the first octet blinking in the panel display.
10.
Using the number pad, enter the
first octet number
in the IP Address.
Содержание KP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 4 KP Series...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 KP Series Rev 05 F 01U 304 914...
Страница 12: ...Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 12 KP Series...
Страница 160: ...160 Basic Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 184: ...184 Firmware Download KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 264: ...264 Telephone Interface TIF Operation KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 268: ...268 Keypad Quick Reference KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 288: ...288 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05 Input Power 100 240VAC 50 60Hz...
Страница 292: ...292 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 302: ...302 KP Series Bosch Security Systems Inc Technical Manual F 01U 304 914 Rev 05...
Страница 306: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...