AIRLINE FILTER

PROTECTIONS PROVIDED 

The RPB

®

 Radex

® 

 filter has 6 stages of filter media to help protect the user from solid or liquid 

particulates, such as dusts, mists, or odors 0.5 micron or larger, as well as an optional micro mist 
filter and mainline prefilter. 

LIMITATIONS

The Radex

®

 Airline Filter Part No. 04-900 does not remove Carbon Monoxide and other toxic 

gases/fumes from the compressed air. 

HAZARD LIMITATIONS 

The RPB

®

 Radex

®

 is NOT FOR USE if the air source being supplied to the Radex

®

 has any of 

these conditions: 

 The air source atmosphere contains less than 19.5% oxygen. 

 The air source contains hazardous gases (e.g., carbon monoxide). 

 The temperature is outside the range of 14°F to 140°F (-10°C to +60°C).

STANDARDS AND REGULATIONS

The Radex

®

 Filtration system can help meet requirements for breathing air quality. Refer to 

the following standards and regulations, depending on the location the Radex

®

 is being used, 

for more information:

 ANSI/Compressed Gas Association Commodity Specification for Air, G-7.1-1989. 

PROTECTION PROVIDED AND LIMITATIONS

Improper selection, use, or maintenance of respiratory protection 
products can result in injury; life threatening delayed lung, skin or eye 

disease; or death. This product is intended for occupational use in accordance with applicable 
standards or regulations for your location, industry, and activity (see Employer Responsibilities, 
page 8.) Familiarity with standards and regulations related to the use of this protective equipment 
is recommended, even if they do not directly apply to you. If self-employed or if used in a non-
occupational setting, refer to Employer Responsibilities and Product User Safety Instructions. 
Go to rpbsafety.com/importantsafetyinformation/ for helpful links to OSHA, EN and AS/NZS 
standards, and other content.

Employers: 

Read this manual and the flow control device Instruction Manual and carry out the 

Employer Responsibilities (page 8).   

Product users:

  Read this manual and the flow control device Instruction Manual and follow the 

Product User Safety Instructions (page 9).

Check website for updates.

 Product manuals are regularly updated. 

Visit www.rpbsafety.com/resources/for the most recent version of this manual before using the 
product.

IMPORTANT SAFETY INFORMATION

WARNING

Содержание RADEX AIRLINE FILTER

Страница 1: ...d this manual and the flow control device Instruction Manual and follow the Product User Safety Instructions page 9 Manuals are regularly updated Make sure the most recent version of manual is availab...

Страница 2: ...Y STATEMENT 20 CONTENTS RPB Safety LLC is an ISO9001 certified company The following signal word and safety symbols are used in this manual and product labeling WARNING indicates a hazardous situation...

Страница 3: ...ual Property contained in this publication including copyright trademarks service marks trade secret and patent rights are reserved RPB Intellectual Property means any patent patented articles patent...

Страница 4: ...CTION PROVIDED AND LIMITATIONS Improper selection use or maintenance of respiratory protection products can result in injury life threatening delayed lung skin or eye disease or death This product is...

Страница 5: ...facturer instruction manual for recommendations on setting up the compressor for breathing air and for suitable in line air purifying sorbent beds and filters The compressor filters and oil level shou...

Страница 6: ...ure must be read from a reliable pressure gauge while the respirator has air flowing through it as required by applicable standards and regulations Refer to the instruction manual for the respirator f...

Страница 7: ...8 BREATHING TUBE ASSEMBLY AND FLOW CONTROL DEVICE 7 BREATHING AIR LINE 4 RADEX AIRLINE FILTRATION SYSTEM 5 GX4 GAS MONITOR 1 SUPPLIED AIR COMPRESSOR 2 SUPPLIED AIR LINE TO FILTER 6 POINT OF ATTACHMEN...

Страница 8: ...pecific airborne hazards with consideration of workplace and user factors and with an Assigned Protection Factor APF that meets or exceeds the required level for employee protection select welding fac...

Страница 9: ...tened securely Air will be released when pressure in the filter exceeds 150 psig 10 3 Bar If the hole is plugged with something other than the pressure relief valve excess pressure could cause the ves...

Страница 10: ...nant concentrations do not exceed those allowed by applicable regulations and standards for supplied air respirators Make sure the work area is ventilated and the work area and the breathing air suppl...

Страница 11: ...mount will only fit in two positions the arrows must align before locking Turn the filter in a clockwise direction and lock into position You will hear a click when the base is in the final position...

Страница 12: ...mounting onto the Radex Airline Filter Use thread sealant on all fittings Fit the complete regulator assembly onto the top of the Radex Airline Filter lid using a 17mm wrench Fit the pressure relief v...

Страница 13: ...Pressure Gauge into the 04 965 6 Outlet Manifold and tighten Thread all six Couplers into the 04 965 Manifold and tighten Thread the completed Six Outlet Manifold assembly into filter lid and tighten...

Страница 14: ...High Flow Regulator 04 962 are optional attachments for environments that are humid or have excessive moisture or have oil or other fine particulates in the air They can all be used together or indivi...

Страница 15: ...OR ASSEMBLY FIGURE 4 5 FIGURE 4 6 To fit the Auto Drain Unit screw the unit onto the elbow connector on the draining valve Make sure the unit is straight down so it will drain properly FIGURE 4 4 FITT...

Страница 16: ...nnections should be sealed using liquid thread sealant If the Radex Airline Filter is hard piped an isolation valve must be used to enable depressurization for servicing MAINTENANCE Drain Moisture Dai...

Страница 17: ...minants do not clean with volatile chemicals Irritation or sickness may result from lack of cleaning the inside of the Radex housing 5 Check the o rings 04 919 and replace if damaged 6 Insert a new fi...

Страница 18: ...18 RADEX AIRLINE FILTER 1 2 3 11 4 5 7 6 8 10 9 18 12 17 13 14 FIGURE 6 1 PARTS AND ACCESSORIES 16 19 22 28 23 27 26 29 30 15 20 21 31 32 24 25...

Страница 19: ...or 04 927 04 929 20 Brass Elbow 04 928 21 Auto Drain Unit 04 924 22 Auto Drain Assembly for 04 924 04 931 23 Super High Flow Regulator 04 962 24 Six Outlet Upgrade Kit inc 5 6 7 23 04 960 25 Six Outle...

Страница 20: ...ted defect occurs RPB will repair or replace the defective Product or a component of the Product in its sole discretion This repair or replacement remedy is the sole and exclusive remedy under this li...

Страница 21: ...21 NOTES...

Страница 22: ...22 RADEX AIRLINE FILTER NOTES...

Страница 23: ...23 NOTES...

Страница 24: ...e value AIR QUALITY MONITORING Do you need an intelligent gas monitor that can give you complete confidence in the air you and your employees are breathing The RPB GX4 Gas Monitor has the ability to d...

Отзывы: