background image

20

RADEX

  

AIRLINE FILTER

LIMITED WARRANTY

RPB

®

 warrants that its Products will be free from defects in materials and workmanship for one (1) 

year, subject to the terms of this limited warranty.  The Products are sold only for commercial use, 
and no consumer warranties apply to the Products. This limited warranty is for the benefit of the 
original Product purchaser, and cannot be transferred or assigned. This is the sole and exclusive 
warranty provided by RPB

®

, and ALL CONDITIONS AND IMPLIED WARRANTIES (INCLUDING ANY 

WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE) ARE EXCLUDED 
AND DISCLAIMED FROM WARRANTY COVERAGE.  RPB’s

®

 limited warranty coverage does not apply 

to damage resulting from accident, improper use or misuse of the Products, wear and tear resulting 
from the normal use of the Products, or the failure to properly maintain the Products.

RPB’s

®

 limited warranty coverage runs from the original date of purchase of the Products, and 

applies only to warranted defects which first manifest themselves and are reported to RPB

®

 within 

the warranty period.  RPB

®

 retains the right to determine to its reasonable satisfaction whether any 

claimed defect is covered by this limited warranty.

If a warranted defect occurs, RPB

®

 will repair or replace the defective Product (or a component of the 

Product), in its sole discretion.  This “repair or replacement” remedy is the sole and exclusive remedy 
under this limited warranty, and under no circumstances shall RPB’s

®

 liability under this limited 

warranty exceed the original purchase price for the Products (or the applicable component). RPB

®

 has 

no responsibility for incidental or consequential damages, including loss of use, maintenance and other 
costs, and ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES ARE EXCLUDED AND DISCLAIMED 
from this limited warranty.  Contact RPB

®

 to obtain warranty service. Proof of purchase must be 

provided to obtain warranty service.  All costs of returning the Products to RPB

®

 for warranty service 

must be paid by the purchaser.

RPB

®

 reserves the right to improve its Products through changes in design or materials without being 

obligated to purchasers of previously manufactured Products.

LIABILITY

RPB

®

 Safety cannot accept any liability of whatsoever nature arising directly or indirectly from 

the use or misuse of RPB

®

 Safety products, including purposes that the products are not designed 

for. RPB

®

 Safety is not liable for damage, loss or expense resulting from the failure to give advice 

or information or the giving of incorrect advice or information, whether or not due to RPB

®

 

Safety’s negligence or that of its employees, agents or subcontractors.

Содержание RADEX AIRLINE FILTER

Страница 1: ...d this manual and the flow control device Instruction Manual and follow the Product User Safety Instructions page 9 Manuals are regularly updated Make sure the most recent version of manual is availab...

Страница 2: ...Y STATEMENT 20 CONTENTS RPB Safety LLC is an ISO9001 certified company The following signal word and safety symbols are used in this manual and product labeling WARNING indicates a hazardous situation...

Страница 3: ...ual Property contained in this publication including copyright trademarks service marks trade secret and patent rights are reserved RPB Intellectual Property means any patent patented articles patent...

Страница 4: ...CTION PROVIDED AND LIMITATIONS Improper selection use or maintenance of respiratory protection products can result in injury life threatening delayed lung skin or eye disease or death This product is...

Страница 5: ...facturer instruction manual for recommendations on setting up the compressor for breathing air and for suitable in line air purifying sorbent beds and filters The compressor filters and oil level shou...

Страница 6: ...ure must be read from a reliable pressure gauge while the respirator has air flowing through it as required by applicable standards and regulations Refer to the instruction manual for the respirator f...

Страница 7: ...8 BREATHING TUBE ASSEMBLY AND FLOW CONTROL DEVICE 7 BREATHING AIR LINE 4 RADEX AIRLINE FILTRATION SYSTEM 5 GX4 GAS MONITOR 1 SUPPLIED AIR COMPRESSOR 2 SUPPLIED AIR LINE TO FILTER 6 POINT OF ATTACHMEN...

Страница 8: ...pecific airborne hazards with consideration of workplace and user factors and with an Assigned Protection Factor APF that meets or exceeds the required level for employee protection select welding fac...

Страница 9: ...tened securely Air will be released when pressure in the filter exceeds 150 psig 10 3 Bar If the hole is plugged with something other than the pressure relief valve excess pressure could cause the ves...

Страница 10: ...nant concentrations do not exceed those allowed by applicable regulations and standards for supplied air respirators Make sure the work area is ventilated and the work area and the breathing air suppl...

Страница 11: ...mount will only fit in two positions the arrows must align before locking Turn the filter in a clockwise direction and lock into position You will hear a click when the base is in the final position...

Страница 12: ...mounting onto the Radex Airline Filter Use thread sealant on all fittings Fit the complete regulator assembly onto the top of the Radex Airline Filter lid using a 17mm wrench Fit the pressure relief v...

Страница 13: ...Pressure Gauge into the 04 965 6 Outlet Manifold and tighten Thread all six Couplers into the 04 965 Manifold and tighten Thread the completed Six Outlet Manifold assembly into filter lid and tighten...

Страница 14: ...High Flow Regulator 04 962 are optional attachments for environments that are humid or have excessive moisture or have oil or other fine particulates in the air They can all be used together or indivi...

Страница 15: ...OR ASSEMBLY FIGURE 4 5 FIGURE 4 6 To fit the Auto Drain Unit screw the unit onto the elbow connector on the draining valve Make sure the unit is straight down so it will drain properly FIGURE 4 4 FITT...

Страница 16: ...nnections should be sealed using liquid thread sealant If the Radex Airline Filter is hard piped an isolation valve must be used to enable depressurization for servicing MAINTENANCE Drain Moisture Dai...

Страница 17: ...minants do not clean with volatile chemicals Irritation or sickness may result from lack of cleaning the inside of the Radex housing 5 Check the o rings 04 919 and replace if damaged 6 Insert a new fi...

Страница 18: ...18 RADEX AIRLINE FILTER 1 2 3 11 4 5 7 6 8 10 9 18 12 17 13 14 FIGURE 6 1 PARTS AND ACCESSORIES 16 19 22 28 23 27 26 29 30 15 20 21 31 32 24 25...

Страница 19: ...or 04 927 04 929 20 Brass Elbow 04 928 21 Auto Drain Unit 04 924 22 Auto Drain Assembly for 04 924 04 931 23 Super High Flow Regulator 04 962 24 Six Outlet Upgrade Kit inc 5 6 7 23 04 960 25 Six Outle...

Страница 20: ...ted defect occurs RPB will repair or replace the defective Product or a component of the Product in its sole discretion This repair or replacement remedy is the sole and exclusive remedy under this li...

Страница 21: ...21 NOTES...

Страница 22: ...22 RADEX AIRLINE FILTER NOTES...

Страница 23: ...23 NOTES...

Страница 24: ...e value AIR QUALITY MONITORING Do you need an intelligent gas monitor that can give you complete confidence in the air you and your employees are breathing The RPB GX4 Gas Monitor has the ability to d...

Отзывы: