14
PX5 PAPR
®
To insert the battery into the PX5
®
, open the
battery compartment door on the bottom of
the unit by twisting the knob to “unlocked”.
Slide the battery into the battery
compartment of the PX5
®
by lining up the slot
on the battery with the guide on the inside of
the unit.
FIGURE 2.9
FIGURE 2.10
Close the battery compartment door, making
sure the seal around the door properly seats
and the latch securely engages. The door
must be completely closed and sealed for
the IP 65 rating and to protect the unit from
damage from liquids or debris.
FIGURE 2.11
With the battery door off or open, remove
the old seal. Note the orientation of the lip on
the seal. Place the new seal into position by
stretching it around the door, into the channel
around the edge of the door.
FIGURE 2.12
INSTALL THE BATTERY PACK
CHANGE BATTERY DOOR SEAL
RESPIRATOR SETUP AND CARE
CONTINUED
Inside
of door
Outside
of door
Содержание PX5 PAPR
Страница 31: ...31 NOTES...