background image

25

When the PX5 

®

 is on speed 1, the ball will 

float inside the flow meter. Ensure that it sits 
above the curved line for the altitude and 
temp for where the check is being performed. 
Ex: 4,000ft above sea level and 70°F.

The flow meter levels are grouped by 
temperature and altitude. Ex.: dashed box 
shows levels for different temps at 0ft above 
sea level. Choose the altitude closest to the 
altitude where the check is being performed.

FIGURE 10.3

FIGURE 10.4

HOW TO READ THE FLOW METER LABEL.

Flow Meter Detailed instructions

Determine your location’s elevation and the current temperature. Note that these parameters 
must represent the environment where the air flow check is being conducted, not the work 
environment the unit is to be used in afterwards. If the environment changes after conducting the 
air flow test, the unit will automatically adapt to any changes in air pressure or temperature. 

Refer to an altimeter or lookup table to determine your location’s altitude. Refer to a thermometer 
to find out the current temperature of your environment. Consult your supervisor if you are 
uncertain about any of these parameters. 

Check the green altitude indications to find the value closest to your location’s altitude. Check the 
temperature markings vertically aligned with that altitude indication to find the one closest to the 
temperature of your environment. This is the minimum flow rate marker to be checked to. Insert 
the flow meter into the outlet of the PX5

®

 and rotate 1/2 turn to lock in place. Tilt the PX5

®

 so 

that the flow meter is vertical. Turn on the PX5

®

 leaving it on Speed 1 and let the air stabilize over 

a 30 second period. With the meter still in the vertical position check that the ball is sitting above 
the minimum flow rate marker for your altitude and temperature.

Note that the Airflow Meter is labelled with altitude indications in meters as well as in feet. 
Temperature indications are printed in °F as well as in °C.  Make sure to read the Airflow Meter at 
the proper units.

Do not use the PX5

®

 if the meter does not reach the minimum airflow rate on the flow meter. Low 

airflow will decrease the level of protection provided. 

Содержание PX5 PAPR

Страница 1: ...age 5 PRODUCT USERS Read this manual and the respirator head top Instruction Manual and follow the Product User Safety Instructions page 7 Manuals are regularly updated Make sure this manual is availa...

Страница 2: ...ION AND CLEANING 26 PRODUCT SPECIFICATIONS AND DATA 28 PARTS AND ACCESSORIES 29 WARRANTY AND LIABILITY STATEMENT 30 CONTENTS EXPLANATION OF SIGNAL WORDS AND SYMBOLS The following signal word and safet...

Страница 3: ...trademarks service marks trade secret and patent rights are reserved RPB Intellectual Property means any patent patented articles patent applications designs industrial designs copyrights software sou...

Страница 4: ...s Contaminants or contaminant concentrations are unknown Work area is poorly ventilated PROTECTION PROVIDED AND LIMITATIONS Improper selection fit use or maintenance of this product can result in inju...

Страница 5: ...pply to your selection and use of respirators and other personal protective equipment These may include such things as federal e g OSHA MSHA Canadian Occupational Health and Safety local e g state pro...

Страница 6: ...e knowledgable of applicable regulations Train each PX5 user in the product s use application inspection maintenance storage fitting and limitations in accordance with the content of this Instruction...

Страница 7: ...EADY FOR USE Make sure you have a complete system The PX5 is only one component of a NIOSH approved respirator system Verify that you have all required components for the PX5 to serve as a complete NI...

Страница 8: ...tamination Verify that airborne contaminant concentrations do not exceed those allowed by applicable OSHA EPA or NIOSH regulations and recommendations for powered air purifying respirators or supplied...

Страница 9: ...lications that produce sparks or high heat be sure to use the FR Fire Retardant specific model of the PX5 with the FR belt and spark arrestor in place see Respirator Setup and Care page 12 Confined Sp...

Страница 10: ...hoods and or helmets H Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridge and canisters are replaced before breakthrough occurs I Contains electrical...

Страница 11: ...20 C to 50 C Do not charge the battery outside the recommended temperature limits 32 F to 113 F 0 C to 45 C Do not store the battery outside the recommended temperature limits 4 F to 104 F 20 C to 40...

Страница 12: ...1 blinking LED low charge 2 blinking LEDs medium charge 3 blinking LEDs high charge 3 solid LEDs fully charged approx 95 100 charged FIGURE 2 3 FIGURE 2 4 Fit the battery into the charging station by...

Страница 13: ...location for charging Ensure the location of this mount meets those specified in the recommendations on page 11 INSTALL BATTERY CHARGER ON A WALL FIGURE 2 5 FIGURE 2 6 If required multiple chargers ca...

Страница 14: ...the seal around the door properly seats and the latch securely engages The door must be completely closed and sealed for the IP 65 rating and to protect the unit from damage from liquids or debris FIG...

Страница 15: ...r onto the hinge cross bar Remove the battery door then slide the hinge back into the unit to remove it from the track inside of the battery compartment FIGURE 2 15 FIGURE 2 13 Slide the new hinge int...

Страница 16: ...3 Inspect the seal on the back side of the filter is clean and free of cuts or distortions Some substances such as carbon monoxide can not be filtered out with a PAPR and may require supplied air or...

Страница 17: ...unit with filter in place and pressing on top 1 and bottom 2 until firm You should hear a click and there should be little to no gap visible when clipped TO INSTALL THE HIGH EFFICIENCY FILTER AND PRE...

Страница 18: ...er cover in place Place the filter door back onto the the PX5 Secure the spark arrestor under the tabs on the front of the filter door FIGURE 4 1 FIGURE 4 2 Reattach the spark arrester cover by rotati...

Страница 19: ...ve Remove the filter from the PX5 by pressing on the tab at the bottom end of the filter and lift up Dispose of it in a responsible and safe manor in accordance with regulations Install new filter and...

Страница 20: ...ckwise 1 2 turn to lock into position Make sure that it is fully locked in position BREATHING TUBE Inspect the breathing tube 04 831 and ensure there is no damage and that the o rings are in place and...

Страница 21: ...measurement POWER OFF Press and hold the power button for about 1 second and the unit will turn off POWER BUTTON AND BATTERY INDICATION The battery level is indicated by the battery shaped LED panels...

Страница 22: ...ft in the battery Leave the work area Power the unit off and remove the battery and place on the charger if you have a second battery you can insert it into the device to continue operation The pulsin...

Страница 23: ...iety of belt options for different applications Refer to the parts list for available belt options BELT REPLACEMENT Thread the belt through the belt bracket as shown above note the orientation FIGURE...

Страница 24: ...PX5 The locking tab on the belt bracket should be facing towards the bottom BELT BACKPACK SUPPORT ATTACHMENT FIGURE 9 5 FIGURE 9 6 Turn the PX5 unit on and then orientate the unit so the flow meter is...

Страница 25: ...fer to a thermometer to find out the current temperature of your environment Consult your supervisor if you are uncertain about any of these parameters Check the green altitude indications to find the...

Страница 26: ...r paper will affect its ability to filter the air and could expose users to harmful environments All damaged filters pre filters and spark arresters must be replaced before using the PX5 5 AIRFLOW MET...

Страница 27: ...battery is stored at 4 F to 104 F 20 C to 40 C as the optimal temperature range for storage to maximise the life of the battery The battery door should be closed during storage or when the unit is not...

Страница 28: ...is stored at 4 F to 104 F 20 C to 40 C as the optimal temperature range for storage to maximise the life of the battery BATTERY RUN TIMES Lithium ion HE Filter Speed 1 10 13 hours Speed 2 7 10 hours S...

Страница 29: ...lter 03 892 6 Fan Housing 03 810 7 Battery Door Assembly 03 815 8 Battery Door Seal 03 817 9 Battery Door Hinge Retainer 03 818 10 Battery 03 855 11 Belt and Support Bracket 03 811 12 2 Belt Assembly...

Страница 30: ...the warranty period RPB retains the right to determine to its reasonable satisfaction whether any claimed defect is covered by this limited warranty If a warranted defect occurs RPB will repair or rep...

Страница 31: ...31 NOTES...

Страница 32: ...ile multi purpose respirator system on the planet From welding and grinding to chemical handling the Z Link serves the widest spectrum of industries and applications on the market This is more than a...

Отзывы: